ALTEC AIR, LLC
P1500W Series Air Dryers User’s Guide
Page 62 of 100
P011787 – Rev. S
If air flows from this valve continuously the Unloader Valve is defective and
should be replaced. See sections 11.2 for part detail and 11.5 for ordering
information.
9.7.5
With a 9/16” wrench
connect hose to the Unloader
Valve.
9.7.6
Close Front Panel.
9.8 Measuring Heatless Dryer
Solenoid Voltage
With the Compressor running
:
9.8.1
Open Front Panel (section 8.6 ).
9.8.2
Locate the Heatless Dryer
Cycle Timer.
The timer has three (3) sets of
terminals (from left-to-right):
“
VALVE
” – Left solenoid
“
IN
” – Incoming power
“
VALVE
” – Right solenoid