ALTEC AIR, LLC
P1500W Series Air Dryers User’s Guide
Page 65 of 100
P011787 – Rev. S
With Compressor running:
9.11.3
Verify the Compressor
shuts down when the tank
pressure (
TANK
) reaches
90.0 PSI
.
If the tank pressure (TANK) fails
to reach 90 PSI, see section 0for
troubleshooting information.
With Compressor NOT
running:
9.11.4
Pull the ring handle on the
Safety Relief Valve to release
air pressure from the air tank.
9.11.5
Verify the Compressor
turns on when the tank
pressure (
TANK
) falls to:
25.0 PSI*
for the P1500W, P1500WLP, P1502W, & P1502WLP
models. *
(50 PSI for Dryers using Firmware v2.84 and older)
60.0 PSI
for the P1500WHP & P1502WHP models
9.11.6
Close Front Panel
If the Compressor Cycling fails either test described, it indicates a problem with
the Control Board which will need to be replaced. See sections 11.2 for part
detail and 11.5 for ordering information.