10.2 Six Month Maintenance
MODEL:
LOCATION NAME:
SERIAL NUMBER:
ADDRESS:
DATE INSTALLED:
Maintenance Interval (Months)
Procedure
Section
6
12
18
24
30
Install Six Month Maintenance Kit
P011910
Read & Record Flow Rate (
FLOW
)
8
Measure & Record
Compressor Amp Draw
Measure & Record Incoming Voltage:
110 - 125 VAC
for P1500W, P1500WLP
& P1500WHP models
208 - 230 VAC
for P1502W, P1502WLP
& P1502WHP models
Set System Pressure:
80 PSI
for P1500W, P1500WLP,
P1502W & P1502WLP models
90 PSI
for P1500WHP & P1502WHP
models
0
Set Static Pressure:
17 PSI
for P1500W, P1500WLP,
P1502W & P1502WLP models
60 PSI
for P1500WHP & P1502WHP
models
6
Set Outlet Pressure
6
Test Consistent Heatless Dryer Cycling
Test Fan
Test Compressor ON/OFF Cycling
Test High Compressor Last Run Time Alarm
Test Humidity Alarm & System Shutdown
Test High & Low Outlet Pressure Alarms
Test Air Fittings for Leaks
Visually Inspect Inside & Outside of Unit for Loose
Wiring or Hardware
Maintenance Performed by:
Date of Maintenance:
NOTE:
COPY OR PRINT THIS PAGE AND KEEP IT WITH THE AIR DRYER