PUREGAS, LLC
P1500W2 Series Air Dryers User’s Guide
Page 20 of 100
P012253 – Rev. H
6.5.18
Power the dryer
ON
.
6.5.19
Set the Static Pressure:
6.5.19.1
Pull Static Pressure
Regulator knob out.
6.5.19.2
Turn knob until the
reading on the pressure
gauge is:
117 kPa
for W2 &
W2LP
414 kPa
for W2HP
6.5.19.3
Push knob in to lock.
6.5.20
Set the Outlet Pressure:
6.5.20.1
Pull the Outlet
Pressure Regulator knob
out (or loosen the
retaining nut – LP
Models).
Summary of Contents for P1500W2
Page 2: ......