PUREGAS, LLC
P1500W2 Series Air Dryers User’s Guide
Page 21 of 100
P012253 – Rev. H
6.5.20.2
Turn knob until
Outlet Pressure (
OUTP
)
reading is at the desired
setting.
6.5.20.3
Push knob in to lock
(or tighten the retaining
nut – LP Models).
6.5.21
Check for air leaks:
NOTE:
This is a general procedure that can be applied to any fitting or hose
that has air pressure in it.
DO NOT SOAP TEST THE HUMIDITY
SENSOR FITTING. DAMAGE TO THE SENSOR MAY OCCUR.
With Compressor NOT running:
6.5.21.1
Listen for any ‘hissing’ sounds which may indicate a fitting or hose
air leak.
With Compressor running:
6.5.21.2
Use a 1-inch paint
brush to dab soapy water
on the air fitting or hose
connection to be tested.
If air bubbles appear at the
connection, this indicates that
air is leaking from the
connection.
If any leaks are detected, take steps to seal them off (as necessary):
•
Tighten the fitting
•
Re-connect loose hose
•
Replace the fitting / hose / component