PUREGAS, LLC
P1500W2 Series Air Dryers User’s Guide
Page 29 of 100
P012253 – Rev. H
8.5.4
High Cabinet Temperature Alarm -
Occurs when the temperature in
the cabinet rises above 49°C for
more than ten (10) seconds.
If this alarm is present for three (3) minutes or more, the Compressor will
SHUTDOWN
to protect against damage due to overheating. Once the
temperature lowers to 45°C the Compressor will re-start.
See section 13.12 for troubleshooting information.
8.5.5
High Duty Cycle Alarm –
Occurs when the Duty Cycle
rises above the alarm set point
for more than one (1) minute.
(Default setting is 70%)
See section 13.17 for troubleshooting information.
8.5.6
Total Time Alarm –
Occurs when the Compressor
has reached an 8,000 hour
maintenance interval. Perform
the required maintenance.
See section 10.3 for maintenance information.
8.5.7
High Flow Rate Alarm –
Occurs when the Flow Rate rises
above the alarm set point for
more than one (1) minute.
(Default setting is 42 SCMD for
W2 & W2LP models, 28.3 SCMD for W2HP models.)
See section 13.11 for troubleshooting information.