8.6.2
High Outlet Pressure Alarm Set Point
(Default setting is 83.0 kPa for W models, 51.71 kPa for WLP models &
241.0 kPa for WHP) –
8.6.2.1
Press the Right (
)
Arrow Button to access the
Change Value Screen.
8.6.2.2
Press the Right (
) &
Left (
) Arrow Buttons to
move the underscore
beneath the digit to change.
8.6.2.3
Press the Up (
) & Down (
) Arrow Buttons to change the value of
the selected digit.
8.6.2.4
Press the Right (
) Arrow Button until the underscore disappears.
8.6.2.5
Press the Right (
)
Arrow Button until the
underscore appears under
the correct setting (
YES
or
NO
).
8.6.2.6
Press the Up (
) Arrow to confirm. This will lock in the new setting
value.