PUREGAS, LLC
P1500W2 Series Air Dryers User’s Guide
Page 57 of 100
P012253 – Rev. H
9.2 Measuring Compressor Amp Draw
With the Compressor running:
9.2.1
Open Front Panel (section 8.7 ).
9.2.2
Locate wire #5 coming
directly from the
Compressor.
9.2.3
Use an Amp Meter to
measure the running amps.
With the Compressor running,
the running amps should
measure:
•
6.3 amps or below
for the
P1500W2, P1500W2LP &
P1500W2HP models
•
3.2 or below
for the P1502W2, P1502W2LP & P1502W2HP models
9.2.4
Close Front Panel.
If the Compressor measures over running amps indicated above, see section
13.16 for troubleshooting information.
WARNING!
Internal surfaces may be hot
. Use care when coming into contact
with internal components as there is a potential for some these
components to become hot when in operation or standby.