9.4 Measuring Incoming Voltage
9.4.1
Open Front Panel (section
9.4.2
Locate the Incoming
POWER
connector inside
the dryer.
9.4.3
Use a Voltmeter to measure
the voltage (inside dryer):
9.4.3.1
Place the probes
between the Power
Connector and terminal
insulation so that they
touch the metal contacts
for BLACK (BROWN)
wire and WHITE (BLUE) wire.
The voltage should measure:
•
110 - 125 VAC
for the P1500W2, P1500W2LP & P1500W2HP models
•
208 - 230 VAC
for the P1502W2, P1502W2LP & P1502W2HP models
9.4.4
Close Front Panel.
If the incoming voltage measures less than indicated above, it is recommended
that steps be taken at your facility to bring the power to the recommended level of
voltage.
WARNING!
Extreme care should be exercised to avoid contact with live
electrical circuits.
It is highly recommended that you remove all
jewelry before performing any procedures.