PUREGAS, LLC
P1500W2 Series Air Dryers User’s Guide
Page 61 of 100
P012253 – Rev. H
With the Compressor NOT running
:
9.5.5
Use a Voltmeter to measure
across the AC terminals.
Should measure:
•
110 - 125 VAC
for the
P1500W2, P1500W2LP &
P1500W2HP models
•
208 - 230 VAC
for the
P1502W2, P1502W2LP & P1502W2HP models
9.5.6
Use a Voltmeter to measure across the DC terminals.
Should measure
0 VDC
.
9.5.7
Close Front Panel.
If any of the AC voltage measurements are different than indicated above, the
Solid State Relay is defective and should be replaced.
If any of the DC voltage measurements are different that indicated above, the
Control Board may be defective and should be replaced.
See sections 11.1 for part detail and 11.5 for ordering information.