9.14 Testing High Outlet Pressure Alarm
9.14.1
Make a note of the current
Outlet Pressure (
OUTP
)
reading.
9.14.2
Open Front Panel (section
9.14.3
Pull the Outlet Pressure
Regulator knob out (or loosen
the retaining nut – LP
Models).
9.14.4
Turn knob clockwise until
Outlet Pressure (
OUTP
)
reading climbs
over:
•
83 kPa
for P1500W2 & P1502W2 models
•
51.71 kPa
for P1500W2LP & P1502W2LP models
•
241 kPa
for P1500W2HP & P1502WHP models
After one (1) minute, the High Pressure Alarm should appear on the display.
9.14.5
Turn Outlet Pressure Regulator knob counter-clockwise until Outlet
Pressure (
OUTP
) reading
lowers to the reading
recorded in step 9.14.1