10. Maintaining Your Dryer
In order to ensure that your P1500W2 Series Air Dryer continues to operate efficiently
and reliably, PUREGAS recommends performing the following maintenance procedures
at the specified Six Month and 8,000 Hour intervals.
It is also recommended that you print out the included
Six Month Maintenance
(section
and
8,000 Hour Maintenance
(section 10.3 )
log sheets and record all completed
maintenance for historical tracking and reference purposes.
The log sheets include a Section reference column which indicates the User’s Guide
section containing the information about the specific procedure. Please refer to these
sections for detailed procedural information.
NOTE:
When operating at higher ambient temperatures, it is recommended that
maintenance be performed more frequently.
NOTE:
After 16,000 hours of run time, PUREGAS recommends sending in your
Compressors and heatless dryers for a complete and comprehensive rebuild by our
Service Department technicians.
See sections 12.1 and 12.2 for information on
services and contacting PUREGAS.
10.1 Safety & Warning Information
WARNING!
Extreme care should be exercised to avoid contact with live
electrical circuits.
Many procedures performed during installation,
operation, testing, and maintenance of this air dryer require the
equipment to be running, creating a situation for potential electrical
shock. It is highly recommended that you remove all jewelry before
performing any procedures.