10.2 Six Month Maintenance
MODEL:
LOCATION NAME:
SERIAL NUMBER:
ADDRESS:
DATE INSTALLED:
Maintenance Interval (Months)
Procedure
Section
6
12
18
24
30
Install Six Month Maintenance Kit
P011910
Read & Record Flow Rate (
FLOW
)
Measure & Record
Compressor Amp Draw
Measure & Record Incoming Voltage:
•
110 - 125 VAC
for P1500W2,
P1500W2LP & P1500W2HP models
•
208 - 230 VAC
for P1502W2,
P1502W2LP & P1502W2HP models
Set System Pressure:
•
552 kPa
for P1500W2, P1500W2LP,
P1502W2 & P1502W2LP models
•
621 kPa
for P1500W2HP & P1502W2HP
models
Set Static Pressure:
•
117 kPa
for P1500W2, P1500W2LP,
P1502W2 & P1502W2LP models
•
414 kPa
for P1500W2HP & P1502W2HP
models
Set Outlet Pressure
Test Consistent Heatless Dryer Cycling
Test Fan
Test Compressor ON/OFF Cycling
Test High Duty Cycle Alarm
Test Humidity Alarm & System Shutdown
Test High & Low Outlet Pressure Alarms
Test Air Fittings for Leaks
Visually Inspect Inside & Outside of Unit for Loose
Wiring or Hardware
Maintenance Performed by:
Date of Maintenance:
NOTE: