PUREGAS, LLC
P1500W2 Series Air Dryers User’s Guide
Page 96 of 100
P012253 – Rev. H
14.2 Set Point Limits and Defaults
14.2.1
System Adjustments
14.2.2
Alarm Set Points
Description
Minimum
Value
Maximum
Value
Default
Value
Unit of
Measurement
Shutdown
High Flow Alarm
W2 & W2LP models
W2HP models
0
0
57
28.3
42
28.3
SCMD
High Outlet Pressure
Alarm W2 models
W2LP models
W2HP models
3.6
2.14
3.6
138.0
51.71
414.0
83.0
51.71
241.0
kPa
Low Outlet Pressure
Alarm W2 models
W2LP models
W2HP models
3.5
2.07
3.5
137.9
51.64
413.9
45.0
2.07
172.0
kPa
High Humidity Alarm
3
15
10
%
YES
High Duty Cycle Alarm
0
99
70
%
High Cabinet
Temperature Alarm
48.8
Deg C
YES
Compressor Total Run
Time Alarm
8000
Hours
14.2.3
System Operations
Description
ON Value
OFF Value
Default
Value
Unit of
Measurement
Compressor
W & WLP models
WHP models
172*
414.0
620
621.0
kPa
Fan
32
27
Deg C
*
(345 - 620 kPa for Dryers using Firmware v2.84 and older)
Description
Minimum
Value
Maximum
Value
Default
Value
Unit of
Measurement
System Pressure
W2 & W2LP models
W2HP models
551.6
621.0
kPa
Static Pressure
W2 & W2LP models
W2HP models
117.0
414.0
kPa
Outlet Pressure
W2 models
W2LP models
W2HP models
13.8
2.07
13.8
103.4
51.71
414.0
kPa
Alarm Delay
OFF
ON
ON
Startup Delay
0
10
0
Seconds