PUREGAS, LLC
P1500W2 Series Air Dryers User’s Guide
Page 13 of 100
P012253 – Rev. H
6.2 Before You Begin
6.2.1
Carefully inspect the unit, including the shipping box as well as the air
dryer, for ANY DAMAGE CAUSED BY SHIPPING. If any shipping
damage is detected, it is important to file a claim with the shipping
company prior to continuing the installation procedures.
6.2.2
Read the entire
Installing Your Dryer
section to familiarize yourself with
the components and procedures before performing the air dryer installation.
6.2.3
Verify the installation location of the air dryer:
6.2.3.1
Well ventilated and free from abrasive dust or chemicals.
6.2.3.2
Ambient temperature is between 5° and 30° C (optimal).
NOTE:
Higher temperatures will decrease component lifespan.
6.2.3.3
Meets the following power requirements:
•
15 amp service recommended
•
10 amp slow blow fuse
•
110 - 125 VAC
, 50/60 Hz for P1500W2, P1500W2LP &
P1500W2HP models
•
208 - 230 VAC, 50/60 Hz, 1 P
hase for P1502W2, P1502W2LP &
P1502W2HP models
6.2.4
Notify the alarm center of the installation and potential for alarms during
the process (as necessary).
IMPORTANT!
Performing procedures not described in this User’s Guide or installing
components not supplied by PUREGAS is NOT RECOMMENDED
AND MAY VOID THE WARRANTY.
WARNING!
High Noise
. PUREGAS air dryers are meant to be installed in an
unattended area.
Summary of Contents for P1500W2
Page 2: ......