PUREGAS, LLC
P200W2 Series Dehydrator User’s Guide
Page 35 of 82
P012213 – Rev. F
8.5.3
High Humidity Alarm –
Occurs when the
HUMIDITY
level rises above the alarm set
point. (Default setting is 7.0%)
If the humidity level exceeds the alarm set point for a period of time, the
Dehydrator will go into
SHUTDOWN
to prevent the output of wet air.
See Section 11.9 for troubleshooting information.
8.5.4
High Cabinet Temperature Alarm -
Occurs when the
CAB TEMP
rises above the alarm set point
for more than one (1) minute.
(Default setting is 49
C)
If the cabinet temperature increases to 60
C or higher, the Dehydrator will
go into
SHUTDOWN
to protect against damage due to overheating.
See Section 11.10 for troubleshooting information.
8.5.5
Low Cabinet Temperature Alarm -
Occurs when the
CAB TEMP
drops below the alarm set point
for more than one (1) minute.
(Default setting is 1
C)
If the cabinet temperature decreases to 1
C or lower, the Dehydrator will go
into
SHUTDOWN
to protect against damage due to freezing.
See Section 11.11 for troubleshooting information.
8.5.6
Duty Cycle Alarm -
Occurs when the Duty Cycle
rises above the alarm set point.
(Default setting is 50%)
See Section 11.12 for troubleshooting information.