PUREGAS, LLC
P4200W2 Series Air Dryer User’s Guide
Page 19 of 113
P012308 - Rev. E
6.5.16
Remove the Red Orifice
Plug from the Outlet Pressure
Port.
CAUTION
: Be careful when
removing plug. System may be
pressurized.
6.5.17
Connect the air supply line to the Outlet Pressure Port.
PUREGAS recommends using Installation Kit P011752 to connect your air dryer
to the air supply line (See section 11.6 for detail).
6.5.18
Power the dryer
ON
.
6.5.19
Set the Static Pressure:
6.5.19.1
Pull Static Pressure
Regulator knob out.