PUREGAS, LLC
P4200W2 Series Air Dryer User’s Guide
Page 22 of 113
P012308 - Rev. E
6.5.23
Connect a Common Alarm (as required):
6.5.23.1
Insert the included
Alarm Connector into
either of the two (2)
Alarm Ports.
6.5.23.2
Wire an external
alarm wire pair to the
Alarm Connector as
required:
•
Common
and
N.C.
for
OPEN ON ALARM
operation.
•
Common
and
N.O.
for CLOSE ON ALARM operation.
6.5.24 REGISTER YOUR DRYER. See section 7 for details.
6.6 Installation Checklist
No shipping damage was detected.
Dryer location meets the following requirements:
o
Well ventilated
o
Free from abrasive dust or chemicals
o
Ambient temperature is between 5° and 30° C (optimal)
Shipping block removed from Compressor Tray.
System Pressure is set to 345 KPa (50 PSI).
Static Pressure is set to 138 KPa (20 PSI).
No air leaks are present in the system.
No alarms are present on the Display Panel.
Summary of Contents for P4200W2