PUREGAS, LLC
P4200W2 Series Air Dryer User’s Guide
Page 81 of 113
P012308 - Rev. E
9.15 Testing High Outlet Pressure Alarm
9.15.1
Make a note of the current
Outlet Pressure (
OUTLET
)
reading.
9.15.2
Remove the Front Panel
(section 8.10 ).
With Compressor running:
9.15.3
Pull the Outlet Pressure
Regulator knob out.
9.15.4
Turn knob clockwise until
Outlet Pressure (
OUTLET
)
reading climbs over the alarm
threshold. (section 8.8.5 )
9.15.5
After one (1) minute,
verify that a High Outlet
Pressure Alarm appears on
the display.
9.15.6
Press the
RESET Button
to clear the alarm.
Summary of Contents for P4200W2