PUREGAS, LLC
P4200W2 Series Air Dryer User’s Guide
Page 83 of 113
P012308 - Rev. E
9.16.5
After one (1) minute,
verify that a Low Outlet
Pressure Alarm appears on
the display.
9.16.6
Press the
RESET Button
to clear the alarm.
9.16.7
Turn Outlet Pressure
Regulator knob clockwise
until Outlet Pressure
(
OUTLET
) reading raises to
the reading recorded in step
9.16.1
9.16.8
Push knob in to lock.
9.16.9
Reinstall the Front Panel (section 8.10 ).
If you are unable to create a Low Outlet Pressure Alarm as described, see section
13.8 for troubleshooting information.
Summary of Contents for P4200W2
Page 2: ......