8.7.9
Startup Delay Set Point
(default setting is 0 sec) –
The Startup Delay keeps the compressor from turning on immediately when
the dryer is powered on for up to 10 seconds. This allows multiple dryers to
power on in separate intervals in case of a power loss.
8.7.9.1
Press the Right (
)
Arrow Button to access the
Change Value Screen.
8.7.9.2
Press the Right (
) &
Left (
) Arrow Buttons to
move the underscore
beneath the digit to change.
8.7.9.3
Press the Up (
) & Down (
) Arrow Buttons to change the value of
the selected digit.
8.7.9.4
Press the Right (
) Arrow Button until the underscore disappears.
8.7.9.5
Press the Right (
)
Arrow Button until the
underscore appears under
the correct setting (
YES
or
NO
).
8.7.9.6
Press the Up (
) Arrow to confirm. This will lock in the new setting
value.
8.7.10
Pressure Gauge
–
This is an information screen
only and will not time-out,
returning to the cycling
information screens. It also
masks air Dryer alarms while in use. This screen can be used during Air
Dryer troubleshooting.