PUREGAS, LLC
P550W2 Series Air Dryers User’s Guide
Page 57 of 99
P012226 – Rev. F
9.2 Measuring Compressor Amp Draw
With the Compressor running:
9.2.1
Open Panel (see section 8.8 ).
9.2.2
Locate wire #5 coming
directly from the compressor.
9.2.3
Use an Amp Meter to
measure the running amps.
With the compressor running, the
running amps should measure
5.0 amps or below
.
9.2.4
Close Panel.
If the compressor measures over 5.0 running amps, see section 13.16 for
troubleshooting information.
WARNING!
Internal surfaces may be hot
. Use care when coming into contact
with internal components as there is a potential for some these
components to become hot when in operation or standby.