PUREGAS, LLC
P550W2 Series Air Dryers User’s Guide
Page 68 of 99
P012226 – Rev. F
9.11 Testing High Duty Cycle Alarm
CAUTION
: Be careful when removing Air hose. System is pressurized.
NOTE:
For this test, allow the Display Screen to cycle through the information
screens.
9.11.1
Allow the Compressor to run and then turn off.
9.11.2
Immediately after the
Compressor turns off,
disconnect the hose indicated
until the Compressor starts
running again.
A High Duty Cycle alarm should
appear on the System Screen.
9.11.3
Re-connect the hose.
9.11.4
Press the
RESET Button
to clear the alarm.
If you are unable to create a High Duty Cycle alarm as described, see section
13.18 for troubleshooting information.
Summary of Contents for P550W2 Series
Page 2: ......