PUREGAS, LLC
P550W2 Series Air Dryers User’s Guide
Page 30 of 99
P012226 – Rev. F
8.6.4
High Cabinet Temperature Alarm -
Occurs when the temperature in
the cabinet rises above 49°C for
more than ten (10) seconds.
If this alarm is present for three (3) minutes or more, the Compressor will
SHUTDOWN
to protect against damage due to overheating. Once the
temperature lowers to 45°C the Compressor will re-start.
See section 13.12 for troubleshooting information.
8.6.5
High Duty Cycle Alarm –
Occurs when the Duty Cycle
rises above the alarm set point.
(Default setting is 70%)
See section 13.17 for troubleshooting information.
8.6.6
Compressor Total Hour Alarm –
Occurs when the compressor has
reached an 8,000 hour
maintenance interval. Perform
the required maintenance.
See section 10.3 for maintenance information.
8.6.7
High Flow Rate Alarm –
Occurs when the Flow Rate
(
FLOW
) rises above the alarm
set point for more than one (1)
minute.
(Default setting is 14 SCMD)
See section 13.11 for troubleshooting information.