P550W2 Series Air Dryers User’s Guide
Page 95 of 99
P012226 – Rev. F
14.2 Set Point Limits and Defaults
14.2.1
System Adjustments
14.2.2
Alarm Set Points
Description
Minimum
Value
Maximum
Value
Default
Value
Unit of
Measurement
Shutdown
High Flow Alarm
0
25
14
SCMD
High Outlet Pressure
Alarm (LP UNITS)
3.6
(2.14)
137.9
(51.71)
69
(51.71)
KPa
Low Outlet Pressure
Alarm (LP UNITS)
3.5
(2.07)
137.8
(51.64)
14
(2.07)
KPa
High Humidity Alarm
3
15
10
%
YES
High Duty Cycle Alarm
0
99
70
%
High Cabinet
Temperature Alarm
48.9
Deg C
YES
Compressor Total Run
Time Alarm
8000
Hours
14.2.3
System Operations
Description
ON Value
OFF Value
Default
Value
Unit of
Measurement
Compressor
137.9
344.7
KPa
Fan
32.2
26.7
Deg C
Description
Minimum
Value
Maximum
Value
Default
Value
Unit of
Measurement
System Pressure
345
KPa
Static Pressure
117
KPa
Outlet Pressure
(LP UNITS)
13.8
(2.07)
103.4
(51.71)
KPa
Alarm Delay
OFF
ON
ON
Startup Delay
0
10
0
Seconds