PUREGAS, LLC
P6500W Air Dryer User’s Guide
Page 18 of 88
P010452 – Rev. Q
6.5.13.5
Plug the power cord
back into the power
outlet.
6.5.14
Reinstall the Top Cover back onto the dryer.
6.5.15
Turn the dryer power
ON
.
NOTE
: Both system
compressors and heatless
dryers will start, creating air
flow through the red outlet
pressure orifice.
6.5.16
Set the System Pressures:
System 1 & System 2 are adjusted and set independently.
Perform the following steps for System 1 (left) and then repeat the steps for
System 2 (right).
With Compressor running:
6.5.16.1
Pull the Capacity
Control Valve knob out.