Connect the air supply line
to the dryer.
CAUTION
: Be careful when
removing outlet plug. System may
be pressurized.
PUREGAS recommends using Installation Kit P011752 to connect your dryer to
the air supply line (See section 11.6 for detail).
6.5.20
Turn the dryer
ON
.
6.5.21
Set the Static Pressure:
6.5.21.1
Pull Static Pressure
Regulator knob out.
6.5.21.2
Turn knob until the
reading on the pressure
gauge is
17 PSI
.
6.5.21.3
Push knob in to lock.