8.5.5 High Cabinet Temperature Alarm -
Occurs when the temperature in the
upper circuit board compartment rises
above 140°F for more than one (1)
minute.
If this alarm is present for one (1) minute or more, the air dryer will go into
SHUTDOWN
mode to protect against damage due to overheating.
See section 13.10 for troubleshooting information.
8.5.6 High Humidity Alarm –
Occurs when the Humidity level rises
above the alarm set point for more than
one (1) minute.
(Default setting is 10.0%)
If this alarm is present for one (1) minute or more, the air dryer will go into
SHUTDOWN
mode to prevent saturated air from being delivered to the
supply line.
See section 13.11 for troubleshooting information.
8.5.7 Compressor Excessive Run Time Alarm –
Occurs when the compressor takes
longer to pressurize the air tank than the
set point for the alarm. (Default setting
is 3:00 minutes)
See section 13.17 for troubleshooting information.
8.5.8 Compressor Total Hour Alarm –
Occurs when the compressor has reached an
8,000 hour maintenance interval. Perform
the next required maintenance.
See section 10.3 for maintenance information.