PUREGAS, LLC
P6500W Air Dryer User’s Guide
Page 32 of 88
P010452 – Rev. Q
8.6 Adjusting & Resetting Dryer Set Points
Dryer Set Points are simply limits programmed for a specific reading. Once this limit
is reached (or exceeded) this results in an alarm for that reading. Each of these set
points is factory programmed with a default value based on typical usage of the air
dryer. Many of the set points for dryer alarms can be modified to levels more closely
based upon your specific application. Reference Appendix Section 14.2 for Limits
and Defaults.
Press the Up (
) Arrow Button to access the Set Point Adjust screens.
Press the Up (
) & Down (
) Arrow Buttons to navigate through the available
Set Point Adjust screens.
To change a specific Set Point:
8.6.1 High Flow Alarm Set Point
(default setting is 4500 SCFD) –
8.6.1.1
Press the Right (
) Arrow
Button to access the Change
Value Screen.
8.6.1.2
Press the Right (
) &
Left (
) Arrow Buttons to
move the underscore beneath
the digit to change.
8.6.1.3
Press the Up (
) & Down (
) Arrow Buttons to change the value of
the selected digit.
8.6.1.4
Press the Right (
) Arrow Button until the underscore disappears.
This will lock in the new setting value.