P6500W Air Dryer User’s Guide 

 

 

Page 34 of 88  

P010452 – Rev. Q 

8.6.4  High Humidity Alarm Set Point

 (default setting is 10.0%) – 

8.6.4.1  

 

Press the Right (

) Arrow 

Button to access the Change 

Value Screen. 

 

8.6.4.2  

 

Press the Right (

) & 

Left (

) Arrow Buttons to 

move the underscore beneath 

the digit to change. 

8.6.4.3  

 

Press the Up (

) & Down (

) Arrow Buttons to change the value of 

the selected digit. 

8.6.4.4  

 

Press the Right (

) Arrow Button until the underscore disappears.  

This will lock in the new setting value. 

 

 

8.6.5  Excessive Compressor Run Time Alarm Set Point

 (default setting is 3:00 

minutes) – 

8.6.5.1  

 

Press the Right (

) Arrow 

Button to access the Change 

Value Screen. 

 

8.6.5.2  

 

Press the Right (

) & 

Left (

) Arrow Buttons to 

move the underscore beneath 

the digit to change. 

8.6.5.3  

 

Press the Up (

) & Down (

) Arrow Buttons to change the value of 

the selected digit. 

8.6.5.4  

 

Press the Right (

) Arrow Button until the underscore disappears.  

This will lock in the new setting value. 

 

 

Summary of Contents for P6500W

Page 1: ...P010452 Rev Q P6500W Air Dryer User s Guide...

Page 2: ......

Page 3: ...us on the web at www puregas com 2 Introduction PLEASE READ THIS USER S GUIDE THOROUGHLY AND SAVE FOR FUTURE REFERENCE This User s Guide is provided for the benefit of our customers and contains infor...

Page 4: ...tem Pressure 39 8 12 Setting the Static Pressure 40 8 13 Setting the Outlet Pressure 40 8 14 Engaging the Boost Transformer 41 9 Testing Your Dryer 44 9 1 Safety Warning Information 44 9 2 Measuring C...

Page 5: ...3 10 High Cabinet Temperature Alarm 77 13 11 High Humidity 78 13 12 Can t Create a High Humidity Alarm Shutdown 79 13 13 Compressor Doesn t Operate 79 13 14 Compressor Won t Build Pressure 80 13 15 Co...

Page 6: ...ion for these warnings and read them as you encounter them WARNING For your safety all the information in this User s Guide must be followed to minimize the risk of electrical shock and prevent proper...

Page 7: ...TANT Performing routine maintenance as outlined in the Maintaining Your Dryer section will ensure optimal performance over the lifecycle of your air dryer CAUTION Incoming power to dryer must be 190 2...

Page 8: ...dependently interchangeably or simultaneously depending on your pressurized air requirement Other features of the P6500W Air Dryer include a fully digital operating platform offering the most accurate...

Page 9: ...4 000 SCFD single system Power Requirements 190 230 VAC 1 Phase 50 60 Hz Electrical Characteristics Running Amps 15 20 Amp service recommended Outlet Pressure Range 0 15 PSI adjustable Outlet Air Hum...

Page 10: ...ir 5 Humitter Measures the humidity of the compressed air 6 Capacity Control Valve Regulates system pressure and prevents air from bleeding back through the heatless dryer 7 Air Tank Stores dry compre...

Page 11: ...elry before performing any procedures WARNING Internal surfaces may be hot Use care when coming into contact with internal components as there is a potential for some of these components to become hot...

Page 12: ...d and free from abrasive dust or chemicals 6 2 3 2 Ambient temperature is between 40 and 85 F optimal NOTE Higher temperatures will decrease component lifespan 6 2 3 3 Meets the following power requir...

Page 13: ...quired Tools and Materials Large adjustable wrench Medium adjustable wrench 7 16 wrench Band cutters or snips Pipe dope or pipe thread tape Cup of soapy water 1 inch paint brush recommended 6 5 Instal...

Page 14: ...4 Check for loose parts hoses or wiring NOTE If ANY SHIPPING DAMAGE is detected file a claim with the shipping company prior to continuing the installation procedures 6 5 5 Remove the shipping block...

Page 15: ...ify that the red orifice plug is still installed where shown 6 5 8 Install the two 2 purge mufflers shipped loose 6 5 9 Verify that the dryer is powered OFF 6 5 10 Plug the power cord into a 190 230 V...

Page 16: ...measure the voltage by placing the probes between the Circuit Breaker and terminal insulation so that they touch the metal contacts If the voltage measures between 210 230 VAC skip to step 6 5 14 If...

Page 17: ...Locate the Main Power Lead quick disconnects in the top section of the dryer 6 5 13 3 Unplug the Main Power Lead quick disconnects 6 5 13 4 Plug both of the Boost Transformer Lead connectors into the...

Page 18: ...the dryer power ON NOTE Both system compressors and heatless dryers will start creating air flow through the red outlet pressure orifice 6 5 16 Set the System Pressures System 1 System 2 are adjusted...

Page 19: ...he knob until the reading on the pressure gauge is 50 PSI 6 5 16 3 Push the knob in to lock 6 5 17 Let the dryer run until the Humidity drops under 2 on both System 1 and System 2 may take up to 15 mi...

Page 20: ...plug System may be pressurized PUREGAS recommends using Installation Kit P011752 to connect your dryer to the air supply line See section 11 6 for detail 6 5 20 Turn the dryer ON 6 5 21 Set the Static...

Page 21: ...essure Regulator knob out 6 5 22 3 Turn knob until Outlet Pressure OUTP reading is at the desired setting 6 5 22 4 Push knob in to lock 6 5 23 Check for air leaks NOTE This is a general procedure that...

Page 22: ...ing or hose connection to be tested If air bubbles appear at the connection this indicates that air is leaking from the connection If any leaks are detected take steps to seal them off as necessary Ti...

Page 23: ...ing requirements o Well ventilated o Free from abrasive dust or chemicals o Ambient temperature is between 40 and 85 F optimal Operating Power is between 210 230 VAC Shipping block removed from compre...

Page 24: ...the Limited Warranty on your product Once you register you are eligible to receive free technical support as well as updates concerning your PUREGAS products Register Online at www puregas com registr...

Page 25: ...It is highly recommended that you remove all jewelry before performing any procedures WARNING Internal surfaces may be hot Use care when coming into contact with internal components as there is a pote...

Page 26: ...t plugs System may be pressurized PUREGAS recommends using Installation Kit P011752 to connect your air dryer to the air supply line See section 11 6 for detail 8 3 Powering the Dryer ON OFF 8 3 1 POW...

Page 27: ...ches 00 00 One system will be Online ON and the other in STANDBY BOTH Runs both System 1 and System 2 simultaneously SYSTEM 1 ONLY Runs only System 1 and leaves System 2 in Standby SYSTEM 2 ONLY Runs...

Page 28: ...nformation screens unless the HOLD button has been pressed 8 4 5 1 Tank Screen TANK Air Tank pressure fluctuates between 20 50 PSI OUTP Outlet Pressure regulated by the Outlet Pressure Regulator FLOW...

Page 29: ...em LAST RUN How many minutes the System compressor ran during the last Air Tank pressurization cycle TOTAL HR How many hours the System compressor has run since the last Total Hour Reset 8 4 5 4 Syste...

Page 30: ...an one 1 minute Default setting is 6 5 PSI See section 13 7 for troubleshooting information 8 5 3 High Flow Alarm Occurs when the Flow Rate FLOW rises above the alarm set point for more than one 1 min...

Page 31: ...set point for more than one 1 minute Default setting is 10 0 If this alarm is present for one 1 minute or more the air dryer will go into SHUTDOWN mode to prevent saturated air from being delivered t...

Page 32: ...application Reference Appendix Section 14 2 for Limits and Defaults Press the Up Arrow Button to access the Set Point Adjust screens Press the Up Down Arrow Buttons to navigate through the available...

Page 33: ...lue of the selected digit 8 6 2 4 Press the Right Arrow Button until the underscore disappears This will lock in the new setting value 8 6 3 Low Outlet Pressure Alarm Set Point default setting is 6 5...

Page 34: ...elected digit 8 6 4 4 Press the Right Arrow Button until the underscore disappears This will lock in the new setting value 8 6 5 Excessive Compressor Run Time Alarm Set Point default setting is 3 00 m...

Page 35: ...clock time is 8 00 am will cause the dryer to cycle at exactly 8 00 am each day 8 6 6 1 Press the Right Arrow Button to access the Change Value Screen 8 6 6 2 Press the Right Left Arrow Buttons to mo...

Page 36: ...Alarm Delays Set Point The Alarm Delay allows an alarm condition to be present for up to one 1 minute before signaling the alarm This allows the dryer to come out of the alarm condition on its own wit...

Page 37: ...he Top Cover off 8 7 2 Removing Front Panel 8 7 2 1 Depress the latches and pull the Front Panel out 8 8 Connecting to Common Alarm Terminals 8 8 1 Remove Top Cover see section 8 7 1 8 8 2 Connect the...

Page 38: ...rnal wire pair to the specific alarm terminal 8 10 Depressurizing the Dryer 8 10 1 Remove Front Panel see section 8 7 2 8 10 2 Pull the ring handle on the Safety Relief Valve until all air pressure is...

Page 39: ...System 1 System 2 are adjusted and set independently With Compressor running 8 11 1 Remove Front Panel see section 8 7 2 8 11 2 Pull the Capacity Control Valve knob out 8 11 3 Turn the knob until the...

Page 40: ...Static Pressure Regulator knob out 8 12 3 Turn knob until the reading on the pressure gauge is 17 PSI 8 12 4 Push knob in to lock 8 12 5 Reinstall Front Panel 8 13 Setting the Outlet Pressure 8 13 1...

Page 41: ...ulator knob out 8 13 4 Turn knob until Outlet Pressure OUTP reading is at the desired setting 8 13 5 Push knob in to lock 8 13 6 Reinstall Front Panel 8 14 Engaging the Boost Transformer 8 14 1 Turn t...

Page 42: ...Locate the Main Power Lead quick disconnects in the top section of the dryer 8 14 5 Unplug the Main Power Lead quick disconnects 8 14 6 Plug both of the Boost Transformer Lead connectors into the Mai...

Page 43: ...PUREGAS LLC P6500W Air Dryer User s Guide Page 43 of 88 P010452 Rev Q 8 14 7 Reinstall the Top Cover back the dryer 8 14 8 Plug the power cord back into the power outlet 8 14 9 Turn the dryer ON...

Page 44: ...require the equipment to be running creating a situation for potential electrical shock It is highly recommended that you remove all jewelry before performing any procedures WARNING Internal surfaces...

Page 45: ...e 1 System 2 Wire 8 9 2 3 Use an Amp Meter to measure the running amps With the compressor running the running amps should measure 4 0 amps or below 9 2 4 Reinstall Front Panel If the compressor measu...

Page 46: ...be measured 9 3 3 Use a Voltmeter to measure the voltage between the Hot and Neutral wires by placing the probes in the openings in the power connector System 1 Wires 1 2 System 2 Wires 8 7 The volta...

Page 47: ...hat they touch the metal contacts The voltage should measure 210 230 VAC 9 4 4 Reinstall Top Cover If the incoming voltage measures less than 210 VAC it is necessary to engage the Boost Transformer in...

Page 48: ...e across the AC terminals Should measure 0 VAC 9 5 4 Use a Voltmeter to measure across the DC terminals Should measure 12 VDC With the System Compressor NOT running 9 5 5 Use a Voltmeter to measure ac...

Page 49: ...e purge tubes from the System Heatless Dryer 9 6 3 Place your hand beneath the purge fittings to feel for purging air Air should Purge from Tower 1 side Purge from Tower 2 side 30 Seconds later Purge...

Page 50: ...lve 9 7 3 Place your hand beneath the Unloader Valve fitting to feel for air flow Air should NOT flow from this fitting continuously Air should only be released in a short burst when the System compre...

Page 51: ...ls from left to right 106VDC Left solenoid IN Incoming power 106VDC Right solenoid 9 8 3 Use a Voltmeter to measure the DC voltage across each set of 106VDC terminals Continue to measure for up to 45...

Page 52: ...the Wiring Diagram section 14 1 Replace defective fan see sections 11 2 for part detail and 11 7 for ordering information 9 10 Testing Safety Relief Valve 9 10 1 Remove Front Panel see section 8 7 2...

Page 53: ...re TANK reaches 50 0 PSI If the tank pressure TANK fails to reach 50 PSI see section 13 14 for troubleshooting information With Compressor s NOT running 9 11 4 Pull the ring handle on the Safety Relie...

Page 54: ...2 9 12 2 Start timing when the compressor s turns on 9 12 3 Pull the ring handle on the Safety Relief Valve when necessary to keep the Tank Pressure TANK from reaching 50 PSI This prevents the compres...

Page 55: ...BOTH Cycle Mode see section 8 4 2 for details on changing Cycle Mode Test one System at a time System System 1 or System 2 9 13 1 Remove Front Panel see section 8 7 2 9 13 2 Turn the System Circuit Br...

Page 56: ...3 7 After three 3 minutes verify that a Humidity Alarm appears and System goes into SHUTDOWN mode 9 13 8 Replace the Humitter into the Humidity Block 9 13 9 Reinstall Front Panel 9 13 10 Turn the Syst...

Page 57: ...5 1 appears on the display press the HOLD Button on the Front Panel to freeze that screen 9 14 3 Make a note of the current Outlet Pressure OUTP reading With Compressor s running 9 14 4 Pull the Outl...

Page 58: ...the RESET Button to clear the alarm 9 14 9 Reinstall Front Panel If you are unable to create a High Outlet Pressure Alarm as described see section 13 6 for troubleshooting information 9 15 Testing Lo...

Page 59: ...PSI After one 1 minute the Low Pressure Alarm should appear on the display 9 15 6 Turn Outlet Pressure Regulator knob clockwise until Outlet Pressure OUTP reading raises to the reading recorded in ste...

Page 60: ...UR With Compressor s NOT running 9 16 1 Listen for any hissing sounds which may indicate a fitting or hose air leak With Compressor s running 9 16 2 Use a 1 inch paint brush to dab soapy water on the...

Page 61: ...on about the specific procedure Please refer to these sections for detailed procedural information NOTE When operating at higher ambient temperatures it is recommended that maintenance be performed mo...

Page 62: ...o check for any loose or disconnected wiring CAUTION SHUT DOWN IMMEDIATELY FOR REPAIRS if the air compressor s shows any evidence of overheating or presents excessive noise CAUTION Depressurizing the...

Page 63: ...age must be 210 230 VAC 9 4 Test High Low Outlet Pressure Alarms 9 14 9 15 Set System Pressure 50 PSI 8 11 Set Static Pressure 17 PSI 8 12 Set Outlet Pressure 8 13 Test Consistent Heatless Dryer Cycli...

Page 64: ...edure Section 8 000 16 000 24 000 32 000 40 000 Install 8 000 Hour Maintenance Kit P011813 11 6 Install 16 000 Hour Maintenance Kit P011814 11 6 Read Record Flow Rate FLOW 8 4 5 1 Measure Record Compr...

Page 65: ...iption Part Number Quantity Recommend Spare Solid State Relay P010562 2 1 Terminal Block P010200 1 Front Panel Display Assembly P010478 1 LCD Display Only P012105 1 Circuit Breaker P010563 3 1 Discret...

Page 66: ...Quantity Recommend Spare Boost Transformer P012772 1 Heatless Dryer Assembly See section11 3 for detail Pressure Gauge 0 30 PSI P011339 1 Static Pressure Regulator P013203 1 1 Adapter Plate 2 Flow Blo...

Page 67: ...y Parts Description Part Number Quantity Recommend Spare Heatless Dryer P010196 1 Pressure Gauge P010695 1 Solenoid Valve In Kit P011813 See section 11 6 for detail Unloader Valve P010453 1 Cycle Time...

Page 68: ...pt In Kit P011766 See section 11 6 for detail Air Compressor Assembly Left Side Right Side P013263 P013264 1 1 Compressor ONLY P010444 1 1 Spacer 8 Precooler P05663 2 Discharge Hose P05069 2 Capacitor...

Page 69: ...88 P010452 Rev Q 11 5 Frame Section Parts Description Part Number Quantity Recommend Spare Top Cover 1 Front Panel 1 Air Intake Filter In Kit P011766 See section 11 6 for detail Purge Muffler In Kit...

Page 70: ...x Month Maintenance Kit Includes air intake filter compressor mufflers and purge mufflers P011766 2 8 000 Hour Maintenance Kit Includes heatless dryer maintenance kits and compressor maintenance kits...

Page 71: ...ct the PUREGAS Inside Sales Service department to order 800 521 5351 option 2 Fax 303 657 2205 sales puregas com parts puregas com IMPORTANT Instruction for the replacement of individual listed compon...

Page 72: ...place desiccant o rings check valves springs and complete solenoid assembly o Test proper component operation Desiccant Tower Repack o Clean out tower and replace desiccant filter and o ring Circuit B...

Page 73: ...egins with the most likely cause s of the issue Otherwise they start from the simplest possibilities and progress to more complicated ones This troubleshooting guide is designed to be easy to follow a...

Page 74: ...ng the air dryer may be necessary before performing certain procedures NEVER remove pressure sensing tubes from the Control Board without depressurizing the air dryer first or damage to the Control Bo...

Page 75: ...unning from the Control Board to the Display Screen is properly connected at both ends see section 11 1 for Control Board and Display Screen locations Plug in ribbon cable to Control Board and Display...

Page 76: ...UTP reading is higher than the High Outlet Pressure Alarm set point above Replace Control Board section 11 1 if Outlet Pressure OUTP reading is over verified High Outlet Pressure Alarm set point for m...

Page 77: ...t Pressure OUTP reading is under verified Low Outlet Pressure Alarm set point for more than 1 minute and fails to create an alarm 13 9 High Flow Rate Alarm Possible Cause Check Corrective Action Air l...

Page 78: ...gh Humidity Alarm set point section 8 6 4 Over 10 not recommended Heatless Dryer not cycling between towers Verify consistent Heatless Dryer cycling section 9 6 Troubleshoot Inconsistent Heatless Drye...

Page 79: ...ce Control Board if no alarm is created and system does not shut down section 11 1 13 13 Compressor Doesn t Operate Possible Cause Check Corrective Action Defective compressor Measure voltage to compr...

Page 80: ...s between compressor and Air Tank for air leaks section 9 16 Connect tighten or replace leaking component 13 15 Compressor Excessive AMP Draw Possible Cause Check Corrective Action Restriction in air...

Page 81: ...Alarm Possible Cause Check Corrective Action Low System Pressure Verify System Pressure section 8 11 Adjust System Pressure to 50 PSI section 8 11 High Flow condition Verify Flow Rate FLOW reading is...

Page 82: ...set point by 1 minute or more and fails to create an alarm 13 19 Compressor Rapid ON OFF Cycling Possible Cause Check Corrective Action Defective Solid State Relay Measure voltages at Solid State Rel...

Page 83: ...ted all of the potential problems and solutions covered in the Troubleshooting Your Dryer section and you still require further assistance to correct a problem contact PUREGAS Technical Support 800 52...

Page 84: ...PUREGAS LLC P6500W Air Dryer User s Guide Page 84 of 88 P010452 Rev Q 14 Appendix 14 1 Wiring Diagram...

Page 85: ...rm 1 19 9 6 5 PSI High Humidity Alarm 3 0 15 0 10 0 YES Excessive Compressor Run Time Alarm 60 00 59 59 180 00 Seconds 14 2 3 System Operations Description ON Value OFF Value Default Value Unit of Mea...

Page 86: ...by the user and the user in turn should file any damage claim against the carrier All warranty items are F O B Broomfield Colorado Freight charges are the responsibility of the user This warranty sha...

Page 87: ...do 80020 800 521 5351 303 427 3700 Fax 303 657 2233 info puregas com www puregas com 16 2 Sales 800 521 5351 option 2 Fax 303 657 2205 sales puregas com parts puregas com 16 3 Service 800 521 5351 opt...

Page 88: ..._____________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________...

Reviews: