P6500W Air Dryer User’s Guide
Page 46 of 88
P010452 – Rev. Q
9.3 Measuring Voltage to Compressor
9.3.1
Remove Front Panel (see section 8.7.2 )
With the Compressor running:
9.3.2
Locate the power lead wires
to the compressor to be
measured.
9.3.3
Use a Voltmeter to measure
the voltage between the Hot
and Neutral wires by placing
the probes in the openings in
the power connector:
System 1 =
Wires #1 & #2
System 2 =
Wires #8 & #7
The voltage should measure
210 - 230 VAC
.
9.3.4
Reinstall Front Panel.
WARNING!
Extreme care should be exercised to avoid contact with live
electrical circuits.
It is highly recommended that you remove all
jewelry before performing any procedures.