10.2 Six Month Maintenance
MODEL:
P6500W
LOCATION
NAME:
SERIAL NUMBER:
ADDRESS:
DATE INSTALLED:
Maintenance Interval (Months)
Procedure
Section
6 12 18 24 30
Install Six Month Maintenance Kit
P011766
11.6
Read & Record Flow Rate (
FLOW
)
8.4.5.1
Measure & Record
Compressor 1 Amp Draw
9.2
Measure & Record
Compressor 2 Amp Draw
9.2
Measure & Record Incoming Voltage
(must be 210 - 230 VAC)
9.4
Test High & Low Outlet Pressure Alarms
9.14 &
9.15
Set System Pressure (50 PSI)
8.11
Set Static Pressure (17 PSI)
8.12
Set Outlet Pressure
8.13
Test Consistent Heatless Dryer Cycling
9.6
Test Precooler Fans
9.9
Test Safety Relief Valve
9.10
Test Compressor ON/OFF Cycling
9.11
Test Compressor Excessive Run Time Alarms
9.12
Test Humidity Alarm &
System Shutdown
9.13
Test Air Fittings for Leaks
9.16
Clean Precooler Coils
Visually Inspect Inside & Outside of Unit for Loose
Wiring or Hardware
Maintenance Performed by:
Date of Maintenance:
NOTE:
COPY OR PRINT THIS PAGE AND KEEP IT WITH THE AIR DRYER