Always unplug the unit before servicing it in any way.

• 

The water temperature of the water remaining in the unit after use may be high.

• 

Do not submerse the unit in the water, or allow water to enter the inside of the unit.

INSIDE THE BODY OF THE UNIT

Pour excess water out of the unit, but do not allow it to enter the spout guide.  

Wash out the unit with fresh water, using ONLY the cleaning brush and a soft  

cloth as needed.

OUTER SURFACE OF THE UNIT

Wipe the surface of the unit with a soft damp cloth if needed.

WATER TANK

If water spots remain in the water tank, wipe the inside down with a soft cloth. 

Do not use soap or detergents.

AIR FILTER

Gently wipe away debris from the filter with a soft cloth.

ULTRASONIC DISK

Remove spray spout (Fig. 1) and use the enclosed cleaning brush to regularly  

remove build up and deposits from this area (Fig. 2). Diluted white vinegar will 

help to prevent this build up.

• 

Fully dry the inside and outside of the unit before storing it.

• 

DO NOT leave water in the unit.

• 

Store in a cool, dry place.

PROBLEM

SOLUTION

Water mist & humidity are not 

produced.

Power Plug: Unplug and then try again.
Power Failure: When the power is returned, try again.
Tank Installation: Make sure the tank is 

correctly attached.

Air blows but water mist is not 

produced.

Excessive Water: Remove a certain amount of water 

from the tank.
The desired humidity is lower than the current 

temperature: Increase the desired humidity.
Detergent residue in tank: Wash the tank 

out and try again.

Humidity level is low.

The surface of the ultrasonic disk is dirty: Wipe it off 

with a soft, dry cloth. Clean with white vinegar.
The water in the unit is too cold: Replace with cool, but 

not cold water.
Damage on the ultrasonic disk: Exchange the disk.

Warm humidity is not produced.

It may take 10-15 minutes before warm humidity 

is created.

Check to see if base of unit feels warm to the touch. 

If so warm mist is being produced.

The humidity has a bad smell.

Poor maintenance or dirty water: Clean the product 

thoroughly, and fill it with fresh water.

White dust is forming on nearby 

furniture.

Hard water may deposit a certain amount of dust. Dust 

in the air also settles because of added humidity in the 

room. Use distilled water if this becomes a nuisance.

Or order a 

Decalcification Filter (FLTDC)

  

by calling 1.866.603.5900 or  

visiting www.guardiantechnologies.com.

7.   Turn the Humidity Dial to the desired   

       volume of humidity. Toward the right and  

       the humidity level increases; toward the  

       left and the humidity level decreases.

8.   As soon as the Refill LED lights 

      up, turn the unit off and refill the

      water tank.

**Clean the disk with  

    the brush ONLY. No  

    other cleaning tool  

    should be used.  

    BRUSH ONLY. (Fig. 2)