Front Panel Button Functionality
To change ‘Channels’
Press either the up or down button until the 3-digit LED display shows the channel you wish to be on.
Then press both the up and down button together to invoke the ‘Enter’ function.
Lock/unlock buttons
Press the up and down buttons together and hold for 6 seconds to lock, or unlock the buttons
Reset to Factory defaults
Prior to applying power to the device, press and hold the minus button. Then apply power.
Engineering mode
There is a mode called ‘Engineering mode’ that temporarily defaults the device to a specific static IP
address of 192.168.0.88, in the event you are not able to access the device. Prior to applying power,
press and hold the plus button, then apply power.