Thank you for purchasing the innovative PureMate  PM 718 Cool Mist ultrasonic humidifier. We wish you many years of healthy indoor 
air with this efficient and effective product. 

 
Ensure  that  all  safety  precautions  are  followed  when  using  this  electrical  appliance  for  the  proper  operation  of  the  device.  These 
instructions describe the safety precautions to be observed during operation. They are designed to prevent injuries or damage to this 
device. 

 

SAFETY PRECAUTIONS

 

 

The inner ultrasonic transducer is highly sensitive. Do not touch it with bare  fingers or scrape it with metal tools, or it will reduce mist 
output. When cleaning this area please use a small cleaning brush, cotton swab or toothbrush. Do not use hot water as it may  damage 
the missing parts. 

Use proper voltage AC 220~240V 50Hz in UK and Europe. Use of improper voltage may cause fire hazard or electric shock. 

To  prevent  electric  shock,  do  not  dismantle,  repair  or  modify  this  product.  Maintenance  and  cleaning  should  be  followed  exactly  as 
instructed in this manual. In the event of a malfunction, please contact an authorized PureMate maintenance center. 

Do not use in areas where flammable or explosive materials are stored. 

Do  not  place  this  device  in  direct  sunlight  or  near  objects  that  generate  high  temperature  heat.  The  heat  may  cause deformation  or 
warping of the outer casing. Do not operate the unit without water in the basin. 

Do not insert foreign objects into the device. Do not touch the transducer or the lower water basin when the unit is operating. Do not 
scratch the transducer. Do not touch the mist output when producing warm mist. 

Do not submerge this device in water. Water or cleaning liquids may only be used on parts to be cleaned according to the cleaning and 
maintenance instructions. 

Only use lime scale remover or vinegar to clean mineral deposits from the basin or transducer. Do not use any harsh detergents that 
may damage the unit. 

If you smell an abnormal odour please turn off and unplug the unit and call PureMate technical support. 

Do not use fabrics or other materials to cover this device. Obstructed air inlets and outlets will result in improper operation of this unit 
and may result in fire or other damage. 

Do not plug in or pull out the power cable with wet hands. Do not disassemble the base unit. Before cleaning and maintenance, the 
appliance must be disconnected from the main supply. Do not touch water and components in the water basin when the unit is working.  

Children should be supervised to ensure that they do not play with the appliance.  

To prevent interference and damage to other electronic devices, this machine should be placed at least 1 meter away from a computer, 
television, radio or other electronic equipment. 

For safety reasons and to prevent fire or electric shock, unplug the power cord from the electric outlet socket whenever you: 

o

 

Do not use the device for a long period of time. 

o

 

Remove the tank, clean or service the machine or the permanent filter. 

o

 

Move or transport the device. 

If the power cord is damaged, then it must be replaced by a qualified person to prevent electric shock or fire. 

 

 

 

Summary of Contents for PM 718

Page 1: ...PureMat TM ULTRASONIC COOL MIST HUMIDIFIER INSTRUCTION MANUAL SUPER TECH HEALTH 2015 PM718 PureMat TM...

Page 2: ...not touch the transducer or the lower water basin when the unit is operating Do not scratch the transducer Do not touch the mist output when producing warm mist Do not submerge this device in water W...

Page 3: ...llumination button 2 On Off knob OFF ON mist release intensity control 3 Illumination 4 Front panel 5 Lid with a mist release opening 6 Water tank 7 Water inlet 8 Filter cartridge 9 Water tank lid 10...

Page 4: ...make sure that the voltage of electric network corresponds to the unit operating voltage Usage of the unit 1 Remove the lid 5 from the water tank 6 2 Remove the water tank 6 from the unit body 3 Turn...

Page 5: ...nsducer and wait for 2 5 minutes 2 Using a small brush cotton swab or toothbrush gently clean the mineral film from the surface of the transducer 3 Rinse the transducer with clean water 4 Never use sh...

Page 6: ...t and clean the sprayer Abnormal noise is heard during the operation of the humidifier The unit is placed on an uneven or unstable surface Unplug the unit and level the unit body or set in another pla...

Page 7: ...ea 30 m 320 ft Noise level 25dB A Dimensions LxWxH 14 x 26 x 31 cm Weight 1 7 kg 3 74 lbs dry Warranty 1 Year Warranty Safety Certifications CE GS Rohs Reach DISPOSAL OF THIS DEVICE At the end of the...

Page 8: ...r Service at 44 121 270 9423 www PureMate co uk For Return Authorization Number 2 Pack the product in its original carton and in the same manner in which you received it or as identical as possible 3...