PureMate

TM

                                                                               

5

                       

                                                                 PM718 

 

CLEANING AND MAINTENANCE

 

 

Attention! Always switch off and unplug the unit before cleaning. 

 

You can ensure many years of trouble free operation of your  PM 718 humidifier by following a few simple maintenance procedures. If 
your  water  is  hard,  containing  high  concentrations  of  calcium  and  other  minerals,  then  over  a  period  of  time  white  dust  will  start  to 
deposit on the various surfaces in the room. A white, film-like substance will also start to develop in the water basin, on the transducer 
and on the inner surface of the water tank. This white film will impede the proper function of the transducer and the operation of the 
machine. 
 

We recommend the following: 

 

1.  If your water is very hard, we recommend that you boil it first, allow it to cool completely before use in the humidifier. The boiling 

will reduce the mineral concentration in the water. The other option is to use distilled water if your mineral level is still too high. 

2.  If you are using the machine on a daily basis, clean the transducer, water tank and basin once a week. 

 

3.  When the water tank needs a refill, empty the remaining water from the tank and fill it with fresh water. 

 

4.  Clean the whole machine and make sure to keep all the parts completely dry when the machine is not in use. 

 
 

 

How to clean the transducer: 
 

1.  Place 5-10 drops of vinegar on the surface of the transducer and wait for 2-5 minutes. 
2.  Using a small brush, cotton swab or toothbrush, gently clean the mineral film from the surface of the transducer. 
3.  Rinse the transducer with clean water. 
4.  Never use sharp or solid objects for cleaning the transducer.

 

 

How to clean the water basin: 

 

1.  Clean the water with a soft damp cloth. If there is excess film on the  surfaces, then soak the cloth with vinegar and repeat the 

process. 

2.  If there is a film in any of the depressions along the basin, drop a bit of vinegar into depression and clean it out with a brush. 
3.  Rinse the basin with clean water. 

 

How to clean the White Dust & Anti-Microbial Filter: 

 

1.  Remove the filter from the water tank. 
2.  Put some white vinegar into a glass. Soak the filter in the vinegar for about 10 minutes. 
3.  Remove the filter from the glass and shake it several times. 
4.  Clean and rinse the filter once again with fresh water. 

 

If you don’t plan to use the humidifier for a long time, remove the filter from the water tank and let it dry thoroughly. The

n wrap it in 

protective packaging and keep it next to the humidifier in a cool, dry and dark storage space. 

 
 

STORAGE 

 

o

 

If you are not going to use the humidifier for a long time, make sure that all its parts are dry, including the operating chamber of the 

sprayer. 

o

 

Do not store the unit with water in the water tank and in the operating chamber of the sprayer. 

o

 

Clean and dry the filter-cartridge before taking it away for storage. Keep the filter-cartridge in a cool darkened place 

o

 

Keep the humidifier away from children in a dry cool place. 

Summary of Contents for PM 718

Page 1: ...PureMat TM ULTRASONIC COOL MIST HUMIDIFIER INSTRUCTION MANUAL SUPER TECH HEALTH 2015 PM718 PureMat TM...

Page 2: ...not touch the transducer or the lower water basin when the unit is operating Do not scratch the transducer Do not touch the mist output when producing warm mist Do not submerge this device in water W...

Page 3: ...llumination button 2 On Off knob OFF ON mist release intensity control 3 Illumination 4 Front panel 5 Lid with a mist release opening 6 Water tank 7 Water inlet 8 Filter cartridge 9 Water tank lid 10...

Page 4: ...make sure that the voltage of electric network corresponds to the unit operating voltage Usage of the unit 1 Remove the lid 5 from the water tank 6 2 Remove the water tank 6 from the unit body 3 Turn...

Page 5: ...nsducer and wait for 2 5 minutes 2 Using a small brush cotton swab or toothbrush gently clean the mineral film from the surface of the transducer 3 Rinse the transducer with clean water 4 Never use sh...

Page 6: ...t and clean the sprayer Abnormal noise is heard during the operation of the humidifier The unit is placed on an uneven or unstable surface Unplug the unit and level the unit body or set in another pla...

Page 7: ...ea 30 m 320 ft Noise level 25dB A Dimensions LxWxH 14 x 26 x 31 cm Weight 1 7 kg 3 74 lbs dry Warranty 1 Year Warranty Safety Certifications CE GS Rohs Reach DISPOSAL OF THIS DEVICE At the end of the...

Page 8: ...r Service at 44 121 270 9423 www PureMate co uk For Return Authorization Number 2 Pack the product in its original carton and in the same manner in which you received it or as identical as possible 3...

Reviews: