background image

 

PureMate

TM                                                                                                                                                                                          

6      

                                         PM 906 Digital Ultrasonic Humidifier

 

 

CLEANING AND MAINTENANCE

 

 
Attention! Always switch off and unplug the unit before cleaning. 

 

You can ensure many years of trouble free operation of your PM 

906 

humidifier by following a few simple maintenance procedures. If 

your water is hard, containing high concentrations of calcium and other minerals, then over a period of time white dust will  start to 
deposit on the various surfaces in the room. A white, film-like substance will also start to develop in the water basin, on the transducer 
and on the inner surface of the water tank. This white film will impede the proper function of the transducer and the operation of the 
machine. 

 

We recommend the following : 

 
1.  If your water is very hard, we recommend that you boil it first, allow it to cool completely before use in the humidifier. The boiling 

will reduce the mineral concentration in the water. The other option is to use distilled water if your mineral level is still too high. 

2.  If you are using the machine on a daily basis, clean the transducer, water tank and basin once a week. 
3.  When the water tank needs a refill, empty the remaining water from the tank and fill it with fresh water. 
4.  Clean the whole machine and make sure to keep all the parts completely dry when the machine is not in use. 

 

How to clean the transducer: 

 

1.  Place 5-10 drops of vinegar on the surface of the transducer and wait for 2-5 minutes.  
2.  Using a small brush, cotton swab or toothbrush, gently clean the mineral film from the surface of the transducer. 
3.  Rinse the transducer with clean water.

 

4.  Never use sharp or solid objects for cleaning the transducer

 

 

How to clean the water basin: 

 

1.  Clean the water with a soft damp cloth. If there is excess film on the surfaces, then soak the cloth with vinegar and repeat the 

process. 

2.  If there is a film in any of the depressions along the basin, drop a bit of vinegar into depression and clean it out with a brush. 
3.  Rinse the basin with clean water. 

 

How to clean the White Dust & Anti-Microbial Filter: 

 
1.  Remove the filter from the water tank. 
2.  Put some white vinegar into a glass. Soak the filter in the vinegar for about 10 minutes. 
3.  Remove the filter from the glass and shake it several times. 
4.  Clean and rinse the filter once again with fresh water. 

 

If you don’t plan to use the humidifier for a long time, remove the filter from the water tank and let it dry thoroughly. Then wrap it in 
protective packaging and keep it next to the humidifier in a cool, dry and dark storage space. 
 
 

 

STORAGE

 

 

o

 

If you are not going to use the humidifier for a long time, make sure that all its parts are dry, including the operating chamber 
of the sprayer. 

o

 

Do not store the unit with water in the water tank and in the operating chamber of the sprayer. 

o

 

Clean and dry the filter-cartridge before taking it away for storage. Keep the filter-cartridge in a cool darkened place 

o

 

Keep the humidifier away from children in a dry cool place. 
 
 
 
 

Summary of Contents for PM 906

Page 1: ...PureMateTM 1 PM 906 Digital Ultrasonic Humidifier INSTRUCTION MANUAL PureMateTM PM 906 DIGITAL ULTRASONIC COOL WARM MIST HUMIDIFIER WITH IONISER SUPER TECH HEALTH English 2015 PM906...

Page 2: ...lower water basin when the unit is operating Do not scratch the transducer Do not touch the mist output when producing warm mist Do not submerge this device in water Water or cleaning liquids may only...

Page 3: ...tton for setting the mist release intensity 4 Heating button for switching on off the water heating mode 5 Humidity button for setting the relative humidity in the room 6 Timer setting button 7 Displa...

Page 4: ...Humidifier On Off icon 25 Room humidity preset humidity indication 26 Humidity level intensity indication REMOTE CONTROL The PM 906 is equipped with a very useful remote control You can activate the r...

Page 5: ...utton of MIST VOLUME 7 Touch the symbol ION the Negative ion generator works On the LCD display it shows the shape of trees Touch again to stop the function 8 Touch the symbol HEATING the warm mist wi...

Page 6: ...rface of the transducer and wait for 2 5 minutes 2 Using a small brush cotton swab or toothbrush gently clean the mineral film from the surface of the transducer 3 Rinse the transducer with clean wate...

Page 7: ...refill with clean water Power light is on but the machine doesn t work Too much water in the water basin Remove the water tank Take a small cup and remove some of the water from the machine s water ba...

Page 8: ...onsidered normal WARNING If the above recommended solutions do not work please contact PureMate technical support at the telephone number for your region Do not attempt to disassemble repair and reass...

Page 9: ...n its original carton and in the same manner in which you received it or as identical as possible 3 Include proof of purchase inside box along with the Return Authorization Number 4 Label and ship the...