background image

CLEANING AND MAINTENANCE

STORAGE

Attention! Always switch off and unplug the unit before cleaning.

You can ensure many years of trouble free operation of your PM 908 humidifier by following a few simple maintenance procedures.
If your  water  is  hard,  containing  high concentrations of  calcium  and other  minerals,  then over  a  period  of  time  white dust  will start
to deposit on the various surfaces in the room. A white, film - like substance will also start to develop in the water basin, on the
transducer and on the inner surface of the water tank. This white film will impede the proper function of the transducer and the
operation of the machine.  

We recommend the following :
1. If your water is very hard, we recommend that you boil it first, allow it to cool completely before use in the humidifier. The boiling 

will reduce the mineral concentration in the water. The other option is to use distilled water if your mineral level is still too high 

.

2. If you are using the machine on a daily basis, clean the transducer, water tank and basin once a week.
3. When the water tank needs a refill, empty the remaining water from the tank and fill it with fresh water.
4. Clean the whole machine and make sure to keep all the parts completely dry when the machine is not in use.

How to clean the transducer:
1. Place 5 -10 drops of vinegar on the surface of the transducer and wait for 2-5 minutes.
2. Using a small brush, cotton swab or toothbrush, gently clean the mineral film from the surface of the transducer.
3. Rinse the transducer with clean water.
4. Never use sharp or solid objects for cleaning the transducer

How to clean the water basin:

1. Clean the water with a soft damp cloth. If there is excess film on the surfaces, then soak the cloth with vinegar and repeat the 

process.

2. If there is a film in any of the depressions along the basin, drop a bit of vinegar into depression and clean it out with a brush. 
3. Rinse the basin with clean water.

How to clean the White Dust & Anti-Microbial Filter:

2. Remove the filter from the water tank.

1. Filter is the Ceramic Ball inside which can  soften and purify the water.

3. Put some white vinegar into a glass. Soak the filter in the vinegar for about 10 minutes.
4. Remove the filter from the glass and shake it several times.
5.

1.

2.
3.
4.

Clean and rinse the filter once again with fresh water.

If you are not going to use the humidifier for a long time, make sure that all its parts are dry, including the water basin.

Do not store the unit with water in the water tank and in the water basin.
Clean and dry the filter-cartridge before taking it away for storage. Keep the filter-cartridge in a cool darkened place
Keep the humidifier away from children in a dry cool place.

PUREMATE

                                                   

5

PM 908 Digital Ultrasonic Humidifier

 

Summary of Contents for PM 908

Page 1: ...the life of your humidifier You ll find many answers to common problems in our troubleshooting section Review the chart of Troubleshooting Tips before calling our customer service WARNING Ensure that...

Page 2: ...rst unplugging the unit from its electrical outlet DO NOT operate any appliance with a damaged cord or plug after the appliance malfunctions or if it has been dropped or damaged in any manner Return a...

Page 3: ...ER ION AUTO MODE FOUR SPEED TEMP TIMER HUMIDITY ON OFF BUTTON IONISER TIMER MIN MAX MIST HUMIDITY ON OFF ION HUMIDITY TIMER MIST MAX MIN LCD DISPLAY Nozzle Top Cover Handle Water Gauge Water Tank Filt...

Page 4: ...ity Min max humidity button Set Humidity Humidity can be increased from 45 to 75 at increments of 5 Machine checks humidity automatically when it is turn on Constant humidity The machine controls the...

Page 5: ...an the transducer 1 Place 5 10 drops of vinegar on the surface of the transducer and wait for 2 5 minutes 2 Using a small brush cotton swab or toothbrush gently clean the mineral film from the surface...

Page 6: ...st is too low Too much mineral scale in the water basin Clean transducer Water is too dirty or water was kept too long in the tank Clean the water tank and refill with clean water Abnormal noise Vibra...

Page 7: ...21 270 9423 or Email sales puremate co uk for Return Authorization Number Please Pack the product into its original carton and in the same manner in which you received it or as identical as possible I...

Reviews: