Joco
06
PURE-PRO
R
EVERSE
O
SMOSIS
SYSTEM
09
PURE-PRO
R
EVERSE
O
SMOSIS
SYSTEM
PRO
P
URE
DRINKING WATER SYSTEM
Tubing connection diagram
Faucet
Tank
Drain
Input water
CONNECTING THE COLOR TUBING:
A. Connect the WHITE tubing to the water supply connector.
B. Connect the BLUE tubing to the sink top faucet.
C. Connect the BLACK tubing to the drain saddle.
D. Connect the RED tubing to the storage tank.
A
B
C
D
PRO
P
URE
DRINKING WATER SYSTEM
PRO
RE
NG
WAT
ER
SYST
EM
4
Loose the Joco fitting anticlockwise.
5
Remove the membrane housing
cap anticlockwise.
O
6
Remove the membrane by a pincer.
7
Install the membrane by carefully
pushing the spigot end into the
socket at the far end of the housing
until completely in.
To RO system
1
Unplug electricity.
2
Turn off water source.
3
Switch off water tank.
Change membrane
RO102 Manual Flushing Membrane System
RO102 Manual Flushing Membrane System