Reverse osmosis was originally designed to make sea water drinkable for the

navy. It is ideal for anyone on a low sodium diet. An R.O. membrane has a pore

size much smaller than bacteria virus, or the cryptosporidium parasite. When

functioning properly it will remove all microorganisms from tap water and produce

sterile water. Reverse osmosis is the reversal of the natural flow of osmosis. In a

water purification system, the goal is not to dilute the salt solution, but to

separate the pure water from the salt and other contaminants. When the natural

osmotic flow is reversed, water from the salt solution is forced to pass through the

membrane in the opposite direction by application of pressure-thus the term

REVERSE OSMOSIS. Through this process, we are able to produce pure water

by screening out the salts and other contaminants.

What is reverse osmosis

Reverse Osmosis

Pressure

Membrane

Water flow

Q: What is the guarantee on the PurePro system ?

Q: What factors affect the quantity and the quality of the water production?

Pressure

Temperature

Total Dissolved Solids (TDS)

Membrane

Q:

Q:

The PurePro System (excluding filters) is guaranteed for 1 year for material and

workmanship. All defective parts will be replaced free within the first year under
natural breakdown. The membrane has one year pro-rated guarantee.

There are four major variables to consider:
1.

-The greater the water pressure, the better water quantity and

quality it produced. Water pressure of 60 PSI is ideal.

2.

-76 F is the ideal water temperature for R.O. 40 F water will

cause the production of R.O. water to fall to half of that at 76 F. The maximum
water temperature recommended is 85 F.

3.

-The higher the amount of dissolved

contaminants in the water, the lower the quantity of water produced. A high
level of TOTAL DISSOLVED SOLIDS can be overcome with additional water
pressure.

4.

-Different membranes have different characteristics. Some

produce more water than others; some have better contaminant rejection
capabilities; some have greater resistance to chemical abrasion for longer life.
PurePro system includes RE1812-70 The Thin Film Composite (TFC)
membranes combine the best of these characteristics and are considered the
finest membrane in the world.

0

0

0

0

My RO system is not making any water. What should I do?

1.Make sure you plug in electricity.
2.Check the water supply. Make sure it's on.
3.Check if pumps work well.
If none of above occur, please contact a technician at the nearest shop for
assistance.

1.Switch off the water supply and turn on the faucet.

2.Check the water flow from the faucet. If water stop coming out, check the

water storage tank.

Water tank still has water: the tank water pressure is under regular water
pressure

give pressure to the tank.

Why can't my water storage tank make enough water?

FAQ

Summary of Contents for RO800

Page 1: ...Reverse Osmosis 03 Components Selections 04 Cartridge filters 05 The parts of RO800 08 Installation diagram 13 Change filters 14 Change RO membrane 15 Operation regulations 17 FAQ 18 Maintenance check...

Page 2: ...romium mercury sodium cadmium fluoride nitrite nitrate and selenium With your own RO water filter system under your sink working for you twenty four hours a day you can have as much purified water at...

Page 3: ...s will be replaced free within the first year under natural breakdown The membrane has one year pro rated guarantee There are four major variables to consider 1 The greater the water pressure the bett...

Page 4: ...ucet C Within a few minutes up to 15 the water will start to run from the faucet slowly D Let the water run for at least 30 minutes This flushes the carbon filters on first time use E After initial fl...

Page 5: ...removes free chlorine odor organic contaminants pesticides and chemicals that contributed to taste and odor Made in USA High rejection TFC type membrane with the capacity of producing 80 gallons per d...

Page 6: ...Low pressure switch 1st stage filter housing 2nd stage filter housing 3rd stage filter housing Electronic solenoid valve Post carbon filter RO membrane housing RO membrane housing RO membrane housing...

Page 7: ...r run for about 15 minutes to clear the filters PRO PURE DRINKING WATER SYSTEM PRO PURE DRINKING WATER SYSTEM RO800 800GPD Light Commercial RO800 800GPD Light Commercial Build in electrical shut off v...

Page 8: ...the tubing top with the faucet end Then connect the tubing end to the last stage filter as point 4 on page 07 12 Make sure that you complete No 1 to No 11 If so switch on water supply and plug in elec...

Page 9: ...e jaco fittings 2 Turn off the water supply Loosen the stainless steel pipe connector PRO RE NG WA TE R SY ST EM 3 Get feed water connector and connect it to the stainless steel pipe as in the picture...

Page 10: ...liver valve and seal it with Teflon tape for 14 circles Then connector it with the feed water connector 5 Get tubing white connect it with deliver valve and the inlet water supply as point 1 on page 0...