background image

PURE-PRO

R

EVERSE

O

SMOSIS

SYSTEM

07

12

PURE-PRO

R

EVERSE

O

SMOSIS

SYSTEM

PRO

P

URE

DRINKING WATER SYSTEM

PRO

P

URE

DRINKING WATER SYSTEM

4

2

1

3

11.Take tubing white. Wear the concave type screw on tubing white and insert the

tubing shroud as shown in the picture. Connect the tubing top with the faucet
end. Then connect the tubing end to the last stage filter (as point 4 on page 07)

12.Make sure that you complete No. 1 to No. 11. If so, switch on water supply and

plug in electricity.

PS. Do not use drink water from the first made water in the tank.

RO800 800GPD Light Commercial

RO800 800GPD Light Commercial

Tubing connection diagram

1

2

3

4

In

To water storage tank

Drain out

To faucet

Faucet

Tank

Drain out

Input water

Installation diagram

Summary of Contents for RO800

Page 1: ...Reverse Osmosis 03 Components Selections 04 Cartridge filters 05 The parts of RO800 08 Installation diagram 13 Change filters 14 Change RO membrane 15 Operation regulations 17 FAQ 18 Maintenance check...

Page 2: ...romium mercury sodium cadmium fluoride nitrite nitrate and selenium With your own RO water filter system under your sink working for you twenty four hours a day you can have as much purified water at...

Page 3: ...s will be replaced free within the first year under natural breakdown The membrane has one year pro rated guarantee There are four major variables to consider 1 The greater the water pressure the bett...

Page 4: ...ucet C Within a few minutes up to 15 the water will start to run from the faucet slowly D Let the water run for at least 30 minutes This flushes the carbon filters on first time use E After initial fl...

Page 5: ...removes free chlorine odor organic contaminants pesticides and chemicals that contributed to taste and odor Made in USA High rejection TFC type membrane with the capacity of producing 80 gallons per d...

Page 6: ...Low pressure switch 1st stage filter housing 2nd stage filter housing 3rd stage filter housing Electronic solenoid valve Post carbon filter RO membrane housing RO membrane housing RO membrane housing...

Page 7: ...r run for about 15 minutes to clear the filters PRO PURE DRINKING WATER SYSTEM PRO PURE DRINKING WATER SYSTEM RO800 800GPD Light Commercial RO800 800GPD Light Commercial Build in electrical shut off v...

Page 8: ...the tubing top with the faucet end Then connect the tubing end to the last stage filter as point 4 on page 07 12 Make sure that you complete No 1 to No 11 If so switch on water supply and plug in elec...

Page 9: ...e jaco fittings 2 Turn off the water supply Loosen the stainless steel pipe connector PRO RE NG WA TE R SY ST EM 3 Get feed water connector and connect it to the stainless steel pipe as in the picture...

Page 10: ...liver valve and seal it with Teflon tape for 14 circles Then connector it with the feed water connector 5 Get tubing white connect it with deliver valve and the inlet water supply as point 1 on page 0...