Food Service Reverse Osmosis System

Operating Conditions

Minimum and Maximum Operating Conditions

Condition

 

Minimum

 

Maximum

Inlet Pressure 

300 kPa 

875 kPa 

Inlet Temperature 

4°C 

38°C 

Inlet TDS 

2,000 mg/L 

Inlet Hardness 

150 ppm

 

Inlet Iron 

0 mg/L 

0.1 mg/L 

Inlet Manganese 

0 mg/L 

0.05 mg/L 

Inlet pH 

10

 

Dimensions

A

B

Depth

430 mm

513 mm

205 mm

A

B

RET3012-500

CO-S150

CO-UZ150

CO-B150

Summary of Contents for CO-RO3

Page 1: ...APR2019 User Guide Food Service Reverse Osmosis Water Treatment System CO RO3 For correct operation installation it is essential to observe these instructions...

Page 2: ...Pty Ltd 2019 What s Inside Safety Guides 3 The Food Service Reverse Osmosis System 3 Before Installation 4 Tools Materials Required 4 Location of System 5 Installation 6 Care Maintenance 8 Operating C...

Page 3: ...hot or cold temperatures Temperature of the water supply to the reverse osmosis system must be between 4 C 40 F and 38 C 100 F Do not install on hot water lines All new membranes must be flushed for...

Page 4: ...ressure etc Refer to the specifications to determine if your installation is within the limits A water quality analysis can be performed to determine if incoming water requires any treatment Contact y...

Page 5: ...not exposed to freezing temperatures Do not expose unit or tubing to direct sunlight Water Supply To provide supply water to the RO system inlet a feed supply fitting is required or install pipe fitt...

Page 6: ...n 1 5 Air Gap Required Above Flood Rim Inlet white Drain Tube black RO Assembly kg cm2 psi 15 200 150 100 50 0 10 5 0 AUTO SHUT OFF IN IN OUT OUT P O W E R Outlet Holding Tank Connection optional RO M...

Page 7: ...Valve is in the OFF position 6 Rotate the Needle Valve in a counterclockwise motion until the valve is in full Bypass mode 7 Turn on the water supply slowly until the system has filled with water 8 R...

Page 8: ...es of water per day should install external filters not supplied to reduce sediment chlorine and sediment larger than 10 microns Replacement of RO Membrane Elements The functional life of the RO membr...

Page 9: ...m Operating Conditions Condition Minimum Maximum Inlet Pressure 300 kPa 875 kPa Inlet Temperature 4 C 38 C Inlet TDS 2 000 mg L Inlet Hardness 150 ppm Inlet Iron 0 mg L 0 1 mg L Inlet Manganese 0 mg L...

Page 10: ...centrate water runs to drain continuously Plugged prefilter Plugged prefilter Replace plugged prefilter Consider sediment prefilter for non chlorinated applications Leak in product line Find and repai...

Page 11: ...the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure Warranty New Zealand This warranty is given by Puretec Ltd Reg No 44643...

Page 12: ......

Reviews: