HYBRID SERIES
| Filtration & Ultraviolet Disinfection All-in-One Unit
Maintenance Procedure
cont.
5. Slide the Quartz Sleeve
through and out of the top
of the chamber.
6. Clean the Quartz Sleeve
with an alcohol based
cleaner if necessary.
7. Slide the Quartz Sleeve into the top of the chamber and
carefully slide down through the bottom opening. Place the
bottom O-Ring on the Quartz Sleeve and screw the bottom
Aluminium Nut on to the chamber while still holding the
sleeve from the top. Gently tap the sleeve to ensure that it's
sitting firmly on the bottom Aluminium Nut.
8. Place the top O-Ring on the sleeve, insert the spring and
screw on the top nut.
9. Slowly insert UV lamp into chamber through the hole of the
Aluminimum Nut at the top of the chamber. Connect the
lamp connector to the pins on the White Lamp Socket. Do
not let go of the lamp until the lamp is securely connected
to the socket.
Never touch the quartz (glass) and lamp surface as marks
or fingerprints may interfere with UV transmission. If lamp
is soiled, please clean lamp with an alcohol based cleaner.
10. Put lamp connector on the Aluminium Nut end. Connect
the ground wire to the chamber. Plug in the ballast power
connector. The RED LED will be illuminated (when the lamp
life timer is reset in step 12 the LED will turn green).
cont. over page.
1
2
3
valve
IN
OUT
10
mins
4
5
6
Replacing UV Lamp
7
8
Replacing UV Lamp
valve
IN
OUT
3
1
2
3
valve
IN
OUT
10
mins
4
5
6
Replacing UV Lamp
7
8
Replacing UV Lamp
Fig. 9
7
8
9
Replacing UV Lamp
valve
IN
OUT
3
O Ring
9
4
5
O Ring
valve
OUT
10
mins
4
5
6
7
8
9
Replacing UV Lamp
valve
IN
OUT
4
5
O Ring
O Ring
Fig. 8