22
Installation & Operation Manual
Copyright © Puretec Pty Ltd 2020
Troubleshooting Guide
Lamp timer does
not read anything.
•
Unit is unplugged.
•
No power at AC power outlet.
•
Power cord is damaged.
•
Power surge caused damage
to electrical assembly.
•
Plug unit into AC power
outlet.
•
Replace fuse or reset
breaker.
•
Replace power cord.
•
Replace ballast.
Leak detected at
filters.
•
O-ring damaged, deteriorated
or incorrectly installed.
•
O-rings dry.
•
Filter cartridge not centered.
•
Remove the sump, wipe the
O-ring and threads clean.
Ensure the O-ring is fitted
properly, then reinstall.
•
Lubricate O-rings with
suitable sealant.
•
Remove sump, check for
cartridge damage, re-
assemble ensuring cartridge
is centered.
Red lamp blinks
and buzzer
sounds.
•
Lamp has reached or nearing
the maximum lamp life.
•
Lamp is disconnected or
faulty.
•
Replace lamp on or before
lamp counter reached 0.
•
Check lamp connection,
replace if needed.
Display flashing.
•
Power interruption.
•
Reset ballast.
Error Code ‘A3’ on
ballast.
•
Ballast countdown has
reached 0, lamp life expired.
•
Replace lamp.