6
Installation & Operation Manual
Copyright © Puretec Pty Ltd 2020
Installation Requirements
•
Hybrid R models are intended for indoor installation (must be protected from
weather, frost, water and have adequate ventilation).
•
All Puretec Hybrid models should be protected from harsh environments where
overexposure to salt or aggressive chemicals can occur.
•
Cold water line only.
•
Power supply: AC 240V | 50Hz
•
Supply pressure: 300-520 kPa. Install pressure limiting valve if pressure exceeds
520 kPa.
Note: For point of entry installations an approved dual check backflow
prevention device must be installed.
•
Supply temperature 0 - 52 °C (protect from freezing).
•
Alternative fittings may be required if being connected to anything other than
25 mm threads.
Note: Only use thread seal tape. Do not use liquid sealant.
•
Ensure the water supply flow rate does not exceed the rated maximum of the
Hybrid system.
•
Ensure the electrical power supply to the Hybrid system is sufficient, allowing for
other appliances that may be connected to the circuit e.g. pump, and ensuring it
is surge protected, and protected against brown-outs. If in doubt, please consult a
qualified electrician.
•
Use unions at pipe connections to enable easy removal and servicing. Use sufficient
tape to ensure airtight seal and do not over tighten. To prevent strain on the unit
always support heavy inlet and outlet pipes.
•
Where the water being treated contains unusually high levels of dissolved solids
particularly hard water, iron, manganese or biological organisms, a deposit build up
on the quartz sleeve may occur over time. Maximum recommended parameters are
as follows:
Iron:
less than 0.3 mg/L
Hydrogen Sulfide:
less than 0.05 mg/L
Suspended Solids:
less than 10mg/L
Manganese:
less than 0.05 mg/L
Hardness:
less than 110mg/L
Installation Requirements