background image

15 

Copyright © Puretec Pty Ltd 2020

Reverse Osmosis User Guide

Note

: There is no need to disconnect tubing from fittings on the manifold. Remove locking bar 

and pull fittings out. Lubricate O-rings with silicone prior to re-assembly.

Note

: If changing only the prefilter and post filter, the other sumps do not need to be removed.

If changing the membrane elements, the prefilter and post filter should also be changed.

6. 

Remove exhausted prefilter and discard.

Caution

: The person handling the filters and membrane elements must have clean hands to 

keep the system sanitized. The use of sterile/latex gloves is recommended.

7.  If changing membrane elements:

a.  Remove membrane sumps. Remove and discard used elements.

b.   Remove new elements from packaging.

Caution

: Elements contain a food grade preservative. The use of sterile/latex gloves is highly 

recommended.

c. 

Lubricate element O-rings, brine seals, and sump O-rings with silicone lubricant. 

Refer to “Connection Lubrication” on page 8 for correct lubrication procedure of 

elements cartridge.

d.   Securely insert O-ring end of elements into manifold. See Figure 13.

e.   Replace sumps and tighten until it bottoms out.

Note

: The system should be sanitized whenever a membrane element or filter is replaced.

8. 

Sanitize the system.

a.   The manifold should be positioned flat with the sump connections facing up.

b.   Pour a tablespoon (15 millilitres) of chlorine bleach into the centre opening of the 

prefilter sump connection. See Figure 13.

RO Installation Guide

e.  Replace sumps and tighten until it bottoms out.

NOTE: The system should be sanitized whenever a membrane 

a.  The manifold should be positioned flat with the sump 

b.  Pour a tablespoon (15 milliliters) of chlorine bleach into 

the center opening of the prefilter sump connection. See 

a.  Remove new prefilter from packaging. Ensure gaskets are 

secure. Insert prefilter into proper opening on manifold.

b.  Lubricate sump O-ring with silicone lubricant.
c.  With the prefilter element in place, screw the sump into 

the connection. Tighten until it bottoms out.  

a.  To unlock the fittings from the tubing, push down on the 

REPLACEMENT OF THE PREFILTER, 
POSTFILTER, AND RO MEMBRANE ELEMENTS 

Figure 14   

Membrane Element 

Locations 

Prefilter Center Opening

Fig. 13

Summary of Contents for ROS2700

Page 1: ...User Guide Reverse Osmosis Water Treatment System ROS2700 For correct operation installation it is essential to observe these instructions SEPT2020...

Page 2: ...laboratory every six months The laboratory should be certified for testing the specific contaminants of concern For a listing of certified laboratories contact local regulatory agencies Consult your l...

Page 3: ...limits A water quality analysis can be performed to determine if incoming water requires any treatment Contact your dealer installer The filters and membrane elements in the RO system need to be repl...

Page 4: ...AR INSTALL KIT LOCKING BAR DISCONNECT 3 8 INCH COLLET LOCK CLIP 1 2 INCH COLLET LOCK CLIP SOME CONFIGURATIONS MAY NOT INCLUDE ALL COMPONENTS LISTED BELOW TUBING INSTALL KIT 3 8 BLACK TUBING 4 ft 3 8 B...

Page 5: ...RO membrane element Drain Point A suitable drain point is needed for reject water from the RO system A floor drain laundry tub standpipe sump etc are all acceptable If discharging into the utility sin...

Page 6: ...r Gap 1 5 Air Gap Required Inlet 1 2 Natural Drain 3 8 Black Feed Water Valve Cold Water Line Only Carbon Postfilter Product 3 8 Blue RO Assembly Keep to Minimum THE BASIC REVERSE OSMOSIS SYSTEM cont...

Page 7: ...Line Only Feed Pressure Gauge RO Assembly External Prefilter Product Storage Tank To Point of Use Vented to Atmosphere Liquid level float sensor to control feed solenoid valve Feed Solenoid Valve Figu...

Page 8: ...t Be sure it will fit flat against the sink or counter and that there is space underneath for tubing 2 If drilling is needed make a 1 1 2 inch diameter hole Warning To avoid damaging a sink consult a...

Page 9: ...nst the clip to hold the faucet in position Installation Guide ater supply and open a low faucet to d style The installer will determine nstall a valve on the cold water tubing If threaded fittings ar...

Page 10: ...s intended for use only durin installation and troubleshooting of the RO system The pressure gauge should be removed during normal system operation because some regulatory agencies did not evaluate th...

Page 11: ...e Ensure that the support leg is installed on the sumps Installation Guide NOTE Make sure the tubing is pushed past the O rings for a secure fit Also when replacing any tubing cut tubing back 1 4 inch...

Page 12: ...d Connector Symbol Connection Tubing Colour Feed Inlet Natural Concentrate Black Product Blue Warning Be sure to lubricate the manifold ports with silicone lubricant prior to inserting the fittings in...

Page 13: ...side 4 Purge the system Open the faucet and run the water through the RO system for two to eight hours Note A minimum of 2 hour flush is required to remove the food grade preservative After 8 hours pe...

Page 14: ...ystem into a contained area such as a sink or tub 5 Remove the support leg from the three sumps and unscrew the top sump as shown to access the prefilter element The support leg functions as a wrench...

Page 15: ...ain a food grade preservative The use of sterile latex gloves is highly recommended c Lubricate element O rings brine seals and sump O rings with silicone lubricant Refer to Connection Lubrication on...

Page 16: ...w direction arrow aligns with water path Reinsert tubing and collect locks 11 Re connect the fittings to the manifold and lock in position with locking bar 12 Re position the assembly and turn the wat...

Page 17: ...Inlet Turbidity 0 1 NTU Dimensions Performance Specifications Minimum and Maximum Operating Conditions Condition Minimum Maximum Inlet Pressure 40 psi 2 76 bar 80 psi 5 52 bar Inlet Temperature 40 F 4...

Page 18: ...lugged post filter If flow into the post filter is acceptable replace post filter Leak or kink in product line Find and repair leak or kink Concentrate water runs to drain after faucet shut off Plugge...

Page 19: ...19 Copyright Puretec Pty Ltd 2020 Reverse Osmosis User Guide Installation Information 14...

Page 20: ...ed or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure Warranty New Zealand This warranty is given by Puretec Ltd Reg No 4464398 PO Box 875 Cam...

Reviews: