background image

Copyright © Puretec Pty Ltd 2020

Reverse Osmosis User Guide

Location of System

The reverse osmosis system is designed for installation under a sink, usually in the kitchen or 

bathroom. The RO assembly can be placed on the cabinet floor in any position that does not 

apply pressure on the disconnect elbows. The RO product water faucet installs on the sink or on 

the countertop next to the sink.

The RO system can also be located in a location away from the faucet. A nearby water source 
and drain point are required.

Note

: Keep the lengths of tubing short. Longer lengths of tubing will decrease system 

performance. A booster pump can be used on the supply line.

Note

: All plumbing should be done in accordance with state and local plumbing codes. 

Some codes may require installation by a licensed plumber. Check with the local plumbing 
authority prior to installation.

Warning

: All components and tubing should be located in an area which is not exposed to 

freezing temperatures. Do not expose unit or tubing to direct sunlight.

Water Supply

: To provide supply water to the RO system inlet, a feed supply fitting is required 

or install pipe fittings as needed. The feed water valve should be located as close to the 

manifold assembly as possible. USE A POTABLE COLD WATER SUPPLY ONLY. Softened water is 

preferred as it will extend the life of the RO membrane element.

Drain Point

: A suitable drain point is needed for reject water from the RO system. A floor 

drain, laundry tub, standpipe, sump, etc. are all acceptable. If discharging into the utility sink 

or standpipe, an air gap of greater than 1/2 inch above the flood rim must be provided. A sink 

p-trap drain adapter is included to install as an optional drain point where codes permit.

Do not connect the system drain line to the dishwasher drain or near the garbage disposal. Back 

pressure from these units may cause the air gap to overflow.

Faucet

: The faucet should be placed near the sink where drinking water is normally obtained. 

Convenience of use (filling of water pitchers and glasses) and an open area beneath the faucet 
under the sink for attaching product and drain tubing are considerations. A 2 inch diameter flat 

surface is required above and below the installation site. The thickness of mounting surface 

should not exceed 1 1/4 inches. Avoid any strengthening webbing on the underside of the sink.

RO Manifold Assembly

: The manifold can be installed on either the right or left side of the 

under-sink area or cabinet. Installation in the basement is also an option. One possible location 

is near the laundry/utility sink where cold potable water and drain access are close. The location 

chosen should allow adequate clearance and accessibility for membrane element changes.

In restricted under-sink areas, it may be easier to install the faucet first. Allow adequate tubing 
lengths for final system placement.

Installation Guide

Summary of Contents for ROS2700

Page 1: ...User Guide Reverse Osmosis Water Treatment System ROS2700 For correct operation installation it is essential to observe these instructions SEPT2020...

Page 2: ...laboratory every six months The laboratory should be certified for testing the specific contaminants of concern For a listing of certified laboratories contact local regulatory agencies Consult your l...

Page 3: ...limits A water quality analysis can be performed to determine if incoming water requires any treatment Contact your dealer installer The filters and membrane elements in the RO system need to be repl...

Page 4: ...AR INSTALL KIT LOCKING BAR DISCONNECT 3 8 INCH COLLET LOCK CLIP 1 2 INCH COLLET LOCK CLIP SOME CONFIGURATIONS MAY NOT INCLUDE ALL COMPONENTS LISTED BELOW TUBING INSTALL KIT 3 8 BLACK TUBING 4 ft 3 8 B...

Page 5: ...RO membrane element Drain Point A suitable drain point is needed for reject water from the RO system A floor drain laundry tub standpipe sump etc are all acceptable If discharging into the utility sin...

Page 6: ...r Gap 1 5 Air Gap Required Inlet 1 2 Natural Drain 3 8 Black Feed Water Valve Cold Water Line Only Carbon Postfilter Product 3 8 Blue RO Assembly Keep to Minimum THE BASIC REVERSE OSMOSIS SYSTEM cont...

Page 7: ...Line Only Feed Pressure Gauge RO Assembly External Prefilter Product Storage Tank To Point of Use Vented to Atmosphere Liquid level float sensor to control feed solenoid valve Feed Solenoid Valve Figu...

Page 8: ...t Be sure it will fit flat against the sink or counter and that there is space underneath for tubing 2 If drilling is needed make a 1 1 2 inch diameter hole Warning To avoid damaging a sink consult a...

Page 9: ...nst the clip to hold the faucet in position Installation Guide ater supply and open a low faucet to d style The installer will determine nstall a valve on the cold water tubing If threaded fittings ar...

Page 10: ...s intended for use only durin installation and troubleshooting of the RO system The pressure gauge should be removed during normal system operation because some regulatory agencies did not evaluate th...

Page 11: ...e Ensure that the support leg is installed on the sumps Installation Guide NOTE Make sure the tubing is pushed past the O rings for a secure fit Also when replacing any tubing cut tubing back 1 4 inch...

Page 12: ...d Connector Symbol Connection Tubing Colour Feed Inlet Natural Concentrate Black Product Blue Warning Be sure to lubricate the manifold ports with silicone lubricant prior to inserting the fittings in...

Page 13: ...side 4 Purge the system Open the faucet and run the water through the RO system for two to eight hours Note A minimum of 2 hour flush is required to remove the food grade preservative After 8 hours pe...

Page 14: ...ystem into a contained area such as a sink or tub 5 Remove the support leg from the three sumps and unscrew the top sump as shown to access the prefilter element The support leg functions as a wrench...

Page 15: ...ain a food grade preservative The use of sterile latex gloves is highly recommended c Lubricate element O rings brine seals and sump O rings with silicone lubricant Refer to Connection Lubrication on...

Page 16: ...w direction arrow aligns with water path Reinsert tubing and collect locks 11 Re connect the fittings to the manifold and lock in position with locking bar 12 Re position the assembly and turn the wat...

Page 17: ...Inlet Turbidity 0 1 NTU Dimensions Performance Specifications Minimum and Maximum Operating Conditions Condition Minimum Maximum Inlet Pressure 40 psi 2 76 bar 80 psi 5 52 bar Inlet Temperature 40 F 4...

Page 18: ...lugged post filter If flow into the post filter is acceptable replace post filter Leak or kink in product line Find and repair leak or kink Concentrate water runs to drain after faucet shut off Plugge...

Page 19: ...19 Copyright Puretec Pty Ltd 2020 Reverse Osmosis User Guide Installation Information 14...

Page 20: ...ed or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure Warranty New Zealand This warranty is given by Puretec Ltd Reg No 4464398 PO Box 875 Cam...

Reviews: