23
Copyright © Puretec Pty Ltd 2020
SOL-TA Commercial Series User Guide
STby:
Is displayed in alternator systems when a valve is in
standby state.
REGEN Pndg RINSE FILL:
Is displayed whenever a zero-capacity
tank has transferred to an off-line stateand is currently waiting
to initiate the second portion of a regeneration cycle. Viewed only
when Delayed Rinse and Fill is set to ON.
Sometimes there is a need to regenerate the system sooner
than when the system calls for it, usually referred to as manual
regeneration. There may be a period of heavy water usage
because of guests or a heavy laundry day for example.
Immediate Regeneration:
To initiate a manual regeneration
immediately, press and hold the "REGEN" button for three seconds.
The system will begin to regenerate immediately.
Note:
The control valve may be forced through the various
regeneration cycles by pressing the "REGEN" button.
Delayed Regeneration:
To initiate a manual regeneration at the
preset delayed regeneration time, press and release "REGEN". The
words "REGEN TODAY" will flash on the display to indicate that the
system will regenerate at the preset delayed regeneration time.
If you pressed the "REGEN" button in error, pressing the button
again will cancel the request.
If the regeneration time option is set to "on 0" there is no set
delayed regeneration time so "REGEN TODAY" will not activate if
"REGEN" button is pressed.
Note:
For softeners, if brine tank does not contain salt, fill with
salt and wait at least two hours before regenerating.
Step 2CS
Step 3CS
Step 4CS
Step 2CS
Step 3CS
Step 4CS
Manual Regeneration
Manual Regeneration