background image

User Manual

 

PT-PSU12 

 

 

 

Preface 

Read this user manual carefully before using this product. Pictures shown in this 
manual are for reference only. Different model layouts and specifications are subject 
to the physical product. 
This manual is for operation instructions only, not for any maintenance usage. 

In the constant effort to improve our product, we reserve the right to make changes in 
functions or parameters without prior notice or obligation. 
 

Trademarks 

Product model and logo are trademarks. Any other trademarks mentioned in this 
manual are acknowledged as the properties of the trademark owner. No part of this 
publication may be copied or reproduced without the prior written consent. 
 

FCC Statement 

This equipment generates, uses and can radiate radio frequency energy and, if not 
installed and used in accordance with the instructions, may cause harmful 
interference to radio communications. It has been tested and found to comply with 
the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These 
limits are designed to provide reasonable protection against harmful interference in 
a commercial installation. 

Operation of this equipment in a residential area is likely to cause interference, in 
which case the user at their own expense will be required to take whatever measures 
may be necessary to correct the interference. 

Any changes or modifications not expressly approved by the manufacture would void 
the user’s authority to operate the equipment. 

 
 

 

Summary of Contents for PT-PSU12

Page 1: ...User Manual PT PSU12 User Manual Power Manager 12 Port 180W Variable 5 12 24V Model PT PSU12 Designed in Germany 2017 PureLink GmbH All rights reserved VersionV1 0 ...

Page 2: ...ed or reproduced without the prior written consent FCC Statement This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications It has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designe...

Page 3: ...07 2006 EU und 2011 65 EU EMC LVD Electro Magnetic Compatibility Low Voltage Directive PureLink GmbH hereby declares that this product PureTools PT PSU12 complies with Directives 2014 30 EU and 2014 35 EU The full text of the EU Declaration of Conformity is available at the following Internet address http www purelink de ce 4251364706671_CE pdf ...

Page 4: ...install this product near water Do not put any heavy items on the extension cable in case of extrusion Do not remove the housing of the device as opening or removing housing may expose you to dangerous voltage or other hazards Install the device in a place with fine ventilation to avoid damage caused by overheat Keep the module away from liquids Spillage into the housing may result in fire electri...

Page 5: ...not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding plug A polarized plug has two blades with one wider than the other A grounding plug has two blades and a third grounding prong The wide blade or the third prong is provided for your safety If the provide...

Page 6: ...n To prevent electric shock hazard replace grille 17 Do not install this equipment in a confined or building in space such as a book case or similar unit and remain a well ventilation conditions at open site The ventilation should not be impeded by covering the ventilation openings with items such as newspaper table cloths curtains etc 18 WARNING Only use attachments accessories specified or provi...

Page 7: ... Excessive sound pressure from earphones and headphones can cause hearing loss WARNING Listening to music at high volume levels and for extended durations can damage one s hearing In order to reduce the risk of damage to hearing one should lower the volume to a safe comfortable level and reduce the amount of time listening at high levels Headsets should comply with EN 50332 2 requirements for GS c...

Page 8: ... shock do not remove cover or back as there are no user serviceable parts inside Refer servicing to qualified personnel The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance instructions in the literature accompanying the appliance 28 Protective earthing terminal The apparatus should be connected to a mains socket ...

Page 9: ...caution 6 3 2 System Diagram 6 3 3 Connection Procedure 7 4 System Operation 8 4 1 Button Control 8 4 2 RS232 Control 9 4 2 1 RS232 Control Software 9 4 2 2 RS232 Command 11 4 3 GUI Control 15 4 3 1 Control Menu 17 4 3 2 Voltage Setting Menu 18 4 3 3 Network Menu 19 4 3 4 Password Menu 20 4 3 5 GUI Update 21 5 Specification 22 6 Panel Drawing 23 7 Troubleshooting Maintenance 24 8 After Sales Servi...

Page 10: ...witch on off via front panel button RS232 commands or Web based GUI and the output voltage on each output channel can be selected as 5 12 24V DC via the TACT Switch on rear panel RS232 command or web based GUI 1 2 Feature Double input channel designed for ensuring the stable AC source Total 12 output channels and each channel has three kinds of output voltage 5 12 24VDC can be selected Output chan...

Page 11: ...x Screws 4 x Plastic Cushions 2 x Power Cords 12 x DC Power Cables 2 pin Phoenix Connector to DC 12 x 2 pin Phoenix Connectors 1 x 3 pin Phoenix Connector 1 x User Manual Note Confirm if the product and the accessories are all included if not please contact with your dealers ...

Page 12: ...ut voltage is too low or too high 01 12 Output channel switching buttons and Activity LEDs 12 in total Press the button to trun on off the corresponding channel and the corresponding LED will turn green and keep on Long press the button for 3 seconds or more to lock unlock the corresponding channel and then the corresponding LED will flash 3 times Note Pictures shown in this manual are for referen...

Page 13: ...ent selected output voltage is work normally Blinking slowly when the current channel is closed Blinking fastly when the current channel is short circuit or over voltage RS232 Serial port 3 Pin phoenix connector connect with a control device such as PC to control the product via RS232 commands C 24V DC 12V 5V SELECT AC100V 240V Tx Rx RS232 TCP IP 24V AC100V 240V AC1 AC2 DC 12V 5V SELECT 24V DC 12V...

Page 14: ...P Ethernet port connect with PC to control the product via Web based GUI AC1 AC2 2 AC input channels Input voltage is AC100 240V Note Pictures shown in this manual are for reference only different model and specifications are subject to real product ...

Page 15: ...nsmitter PoH Audio Splitter PoH PoC PoC HDBT Receiver HDBT Transmitter HDBT Receiver HDBT Transmitter HDBT Receiver HDBT Transmitter HDBT Receiver 24V 24V 12V 12V 5V AC100V 240V Tx Rx RS232 TCP IP AC100V 240V AC 1 AC 2 01 DC 24V 12V 5V SELECT 02 DC 24V 12V 5V SELECT 03 DC 24V 12V 5V SELECT 04 DC 24V 12V 5V SELECT 05 DC 24V 12V 5V SELECT 06 DC 24V 12V 5V SELECT 07 DC 24V 12V 5V SELECT 08 DC 24V 12V...

Page 16: ...onnect the devices needed to be powered to the DC ports on rear panel Step2 Connect the PC to the RS232 port on rear panel Step3 Connect the PC to the TCP IP port on the rear panel Step4 Connect the power cables to the one or both of AC1 and AC2 input port ...

Page 17: ...l can t be controlled via front panel button RS232 commands and Web based GUI Select the output voltage Press SELECT on corresponding output channel to select the output voltage as 5V 12V or 24V Note After switching the output voltage the output channel will be turned off based on overvoltage protection control and it need to be turned on again via the corresponding output channel switching button...

Page 18: ...RS232 commands via the RS232 control software 4 2 1 RS232 Control Software Installation Copy the control software file to the computer connected with the product Uninstallation Delete all the control software files in corresponding file path Basic Settings Double click the software icon to run this software Here we take the software CommWatch exe as example The icon is showed as below ...

Page 19: ...d as below Please set the parameters of COM number bound rate data bit stop bit and the parity bit correctly and then you are able to send command in Command Sending Area Parameter Configuration area Monitoring area indicates if the command sent works Command Sending area ...

Page 20: ... x 1 12 x Closed Output x V y When y NULL Set the output voltage as x for all output channels x 5 12 24 All Output x V When y 1 12 Set the output voltage as X for the output channel y x 5 12 24 y Output x V Status x When x NULL query the on off status of all output channels 01 Open 02 Closed 03 Closed When x 1 12 query the on off status of the output channel x x Open x Closed Save x Save the curre...

Page 21: ...8 09 10 11 12 State S S S S S S S S S S S S Vm 12 12 12 12 12 12 12 12 12 12 12 12 Over N N N N N N N N N N N N Lock N N N N N N N N N N N N QueryGroup x When x NULL query all groups Out 01 02 03 04 05 06 07 08 09 10 11 12 Vm1 12 12 12 12 12 12 12 12 12 12 12 12 Vm2 XX XX XX XX XX XX XX XX XX XX XX XX When x 1 5 query the group x Out 01 02 03 04 05 06 07 08 09 10 11 12 Vm x 12 12 12 12 12 12 12 12...

Page 22: ... N N N N N N N Name Query the manufacturer XXX Type Query the product model TPUH PSU12 Version Query the software version V x x x Baud x Set the baud rate as x x 1200 2400 4800 9600 19200 38400 57600 115200 When x NULL the default baud rate is 9600 Baud x not change Baud y change to x Lock x When x NULL lock all channels Locking all channel When x 1 12 lock the channel x Locking x channel Unlock x...

Page 23: ...XX XX XX XX XX XX XX XX XX FE Modify product model The command has 18 bytes in total and 16 bytes are effective The digit 0 is used for padding For example FB 54 50 55 48 2D 50 53 55 31 32 00 00 00 20 00 00 FE Note After sending the Output x V y to change the output voltage the corresponding output channel will be switch off the command x should be sent to switch on this output channel again After...

Page 24: ...re This product can be controlled via web based GUI It allows users to interact with the product through graphical icons and visual indicators 1 Connect a PC to the TCP IP port on the rear panel and set its network segment to the same as the default IP of the product 192 168 0 178 port No 4001 Same network segment as the product ...

Page 25: ...User Manual PT PSU12 16 2 Type 192 168 0 178 in your browser it will enter the log in interface shown as below ...

Page 26: ... password user default setting on the log in interface and then click Login to enter Control menu shown as below Select the ON OFF to switch on off the output channel Click the All On to switch on all output channels Click the All Off to switch off all output channels ...

Page 27: ...r Manual PT PSU12 18 4 3 2 Voltage Setting Menu Click Voltage Setting on the top of page to enter voltage setting menu shown as below In this interface you can select 5V 12V or 24V for each output channel ...

Page 28: ... on the top of page to enter network setting menu shown as below In this interface dynamic or static IP mode can be selected Under static IP mode IP address and subnet mask gateway can be set and make sure the IP addresses are different to avoid IP conflict ...

Page 29: ...User Manual PT PSU12 20 4 3 4 Password Menu Click Password on the top of page to enter password menu shown as below In this interface the password can be modified as you need ...

Page 30: ... Type the username and password the same as the GUI log in settings modified password will be available only after rebooting to log in the configuration interface After that click Administration at the source menu to get to Upload Program as shown below Select the desired update file and press Apply it will start upgrading then ...

Page 31: ...V 15W 24V 15W Maximum output power consumption for single supply 110VAC 90W 220VAC 180W Maximum output power consumption for dual supply 180W Control Part Buttons Control Front Panel 01 12 total 12 buttons Rear Panel Total 12 TACT Switches named SELECT RS232 Control RS232 port 3 Pin phoenix connector Baud rate support 1200 2400 4800 9600 default 19200 38400 57600 115200 GUI Control TCP IP port RJ4...

Page 32: ...V 240V AC1 AC2 DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 437 mm 357 mm 44 mm ...

Page 33: ...control device e g a PC through RS232 port Wrong RS232 communication parameters Type in correct RS232 communication parameters Fail or loose connection Make sure the connection is good Broken RS232 port Send it to authorized dealer for checking Cannot control the device via GUI The IP address of control PC and TCP IP port are not on the same network segment Modify control PC s network segment to t...

Page 34: ...fee Warranty expiration Factory applied serial number has been altered or removed from the product Damage deterioration or malfunction caused by Normal wear and tear Use of supplies or parts not meeting our specifications No certificate or invoice as the proof of warranty The product model showed on the warranty card does not match with the model of the product for repairing or had been altered Da...

Page 35: ...User Manual PT PSU12 ...

Page 36: ...Technical Support Phone 49 5971 800299 0 Fax 49 5971 800299 99 Technical Support Hours 8 30 AM to 5 00 PM Monday thru Thursday 8 30 AM to 4 00 PM Friday Write to PureLink GmbH Von Liebig Straße 10 D 48432 Rheine www purelink de info purelink de ...

Reviews: