6.2
RS232 Communication Commands
Communication protocol:
RS232 Communication Protocol
Baud rate: 9600 Data bit: 8 Stop bit: 1 Parity bit: none
Note:
All commands need to be ended with “<CR><LF>”.
In the commands, “[”and “]” are symbols for easy reading and do not need to be typed in
actual operation.
Type the command carefully, it is case-sensitive.
6.2.1
System Commands
Command
Description
Command Example and
Feedback
>GetFirewareVersion
Get firmware version.
<V1.0.0
>SetFactoryReset
Reset to factory default.
<FactoryReset_True
>SetReboot
System reboot.
<Reboot_EN
>SetHelp [Param]
Get the command details.
[Param]= Any command.
>SetHelp
SetHdcpActiveMode
<Set the HDCP bypass from
SRC or SINK
>SetHdcpActiveMode Param
Param = Src,Sink
Src - Active by src
Sink - Active by Sink